MAUDE Adverse Event Report: ARJOHUNTLEIGH POLSKA SP. Z O.O. NIMBUS 3; MATTRESS, AIR FLOTATION, ALTERNATING PRESSURE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARJOHUNTLEIGH POLSKA SP. Z O.O. NIMBUS 3; MATTRESS, AIR FLOTATION, ALTERNATING PRESSURE Back to Search Results
Model Number 152010DAR
Device Problem Air Leak (1008)
Patient Problems Local Reaction (2035); Discomfort (2330)
Event Date 02/05/2017
Event Type  malfunction  
Manufacturer Narrative
This report is report is being filed under exemption (b)(4) by arjohuntleigh (b)(4) on behalf of the importer (b)(4).Additional information will be provided upon the investigation conclusion.
 
Event Description
Arjohuntleigh received an information about an event which occurred with the involvement nimbus 3 system.It was reported that the mattress deflated when in use with the patient.A (b)(6) obese patient, bedridden because of digestive surgery with "hartmann intervention" by laparotomy, needed an air mattress due to an altered skin condition (located at sacrum and back) since the (b)(6) 2017.The mattress was received the (b)(6) at the evening and installed on saturday, the 4th.It was indicated that a leakage in the system occurred was noticed on sunday, the 5th in the afternoon (the source is yet unknown).The mattress was replaced after 3h.As a remedial action, the caregiver located the patient on a chair while waiting for service.This created a discomfort and an aggravation of altered skin condition (fibrin deposition located at the back).Even though a low pressure alarm on the pump was working, the time spent by patient lying on a flat surface remained unknown.
 
Manufacturer Narrative
(b)(4).An investigation was carried out into this complaint.On (b)(6) 2017 arjohuntleigh received an information regarding an event which occurred with the involvement of nimbus 3 system.A patient who was bedridden because of digestive surgery needed an air mattress due to an altered skin condition (located at sacrum and back).On the next day after the installation a leakage in the system was noticed - pump unit was alarming low pressure.The source of mattress leakage was located in mattress cell.Even though a low pressure alarm on the pump was working, the time spent by patient lying on a flat surface remained unknown.As a remedial action, a caregiver placed the patient on a chair while waiting for service.This created a discomfort and an aggravation of altered skin condition (fibrin deposition located at the back).Final assessment of received injury did not consider any serious patient's outcome.When reviewing similar reportable events, we have found no other cases presenting a similar scenario as the one investigated.The event is considered to be an isolated issue.Following the information gathered, it was possible to indicate the reason for mattress deflation - a leakage of the cell occurred.Although the mattress has failed, a designed mitigation factor was fully functional and alerted caregivers about the system malfunction.The staff acted properly by removing the patient from a malfunctioning mattress, however, a period of time spent by the patient on a hard surface is unknown.A remedial action including patient's re-location to the chair with no pressure relief features appears to have led to the deterioration of skin condition, already weakened and prone to injuries.Nimbus 3 system is incorporated with several designed mitigation factors including dedicated pump alarms which are supposed to alert the user in case of system malfunction which may possibly trigger a hazardous situation for the patient.This element of product functionality was still in place at the time of the event.Nevertheless, the therapy with nimbus system represent only one aspect of pressure ulcer management protocol.The procedure should be regularly reviewed by caregiving staff, especially in case of an unexpected failure of one of the protocol's elements (device malfunction).Then, the regimen of care should be re-assessed, focusing on other available aspects of care.Basing on the above, despite a fully functional designed mitigation factor (a low pressure alarm) which was alerting the caregiver, it is suspected that no immediate action was taken and the implemented remedial action towards the patient did not prevent from worsening of patient's condition.Possible sequence of events presented above seems to be the most probable and in line with the event description.The root cause of the reported event is considered to be use error- an incorrectly applied pressure ulcer management and individual patient's assessment.Arjohuntleigh suggests to remind the staff involved of the device labeling, with a special attention paid towards the need of frequent patient's assessment.This is to be communicated to the customer.It has been established that the nimbus 3 system was being used for a patient therapy at the time of the event and has malfunctioned (did not perform up to specification).The system have contributed to a delay in therapy for the patient, however, an incorrectly adjusted patient's care procedure has contributed to the outcome of the event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NIMBUS 3
Type of Device
MATTRESS, AIR FLOTATION, ALTERNATING PRESSURE
Manufacturer (Section D)
ARJOHUNTLEIGH POLSKA SP. Z O.O.
ul. ks. piotra wawrzyniaka 2
komorniki, PL-62 052
PL  PL-62052
Manufacturer (Section G)
ARJOHUNTLEIGH POLSKA SP. Z O.O.
ul. ks. piotra wawrzyniaka 2
komorniki, PL-62 052
PL   PL-62052
Manufacturer Contact
kinga stolinska
ul. ks. piotra wawrzyniaka 2
komorniki, PL-62-052
PL   PL-62052
MDR Report Key6391158
MDR Text Key69757166
Report Number3007420694-2017-00055
Device Sequence Number1
Product Code FNM
Combination Product (y/n)N
Reporter Country CodeFR
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,user f
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 04/10/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/09/2017
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other Caregivers
Device Model Number152010DAR
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? Yes
Date Report Sent to FDA04/10/2017
Distributor Facility Aware Date02/09/2017
Device Age6 YR
Event Location Hospital
Date Report to Manufacturer04/10/2017
Date Manufacturer Received02/09/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured10/05/2010
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Outcome(s) Other;
Patient Age69 YR
-
-