MAUDE Adverse Event Report: ALCON RESEARCH, LTD. - IRVINE TECHNOLOGY CENTER OCUSCAN RXP OPHTHALMIC ULTRASOUND SYSTEM; SYSTEM, IMAGING, PULSED ECHO, ULTRASONIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ALCON RESEARCH, LTD. - IRVINE TECHNOLOGY CENTER OCUSCAN RXP OPHTHALMIC ULTRASOUND SYSTEM; SYSTEM, IMAGING, PULSED ECHO, ULTRASONIC Back to Search Results
Catalog Number 8065741076
Device Problem Incorrect Or Inadequate Test Results (2456)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.(b)(4).
 
Event Description
A customer reported that their diagnostic instrument was not giving accurate measurements.Number of patients involved and impact are unknown.Additional information has been requested, but none has been received to date.
 
Manufacturer Narrative
This complaint file was reviewed by the clinical analyst, who stated the following: ¿a customer reported that the system was not giving accurate measurements.Additional information received from the surgeon stated that the amount of deviation was about 0.50 which was so low that it could be considered as normal.The surgeon did not know the exact name of the patient involved.Another device was thought to be the cause of this deviation.The measurement of axial length measurement has the greatest potential for error in calculating iol power.Traditionally, contact a-scan ultrasonography is used.This measures the time taken for sound to traverse the eye and converts it to a linear value using a velocity formula.Part of the ultrasound beam reflects back from each surface in the eye ¿ cornea, anterior lens, posterior lens, and retina.The reflected beam is translated into an image showing lines (spikes) for each surface.The distance between the corneal and retinal spikes gives the axial length of the eye.The alignment of the a-scan is vitally important.If the alignment is incorrect, the length of the eye will be underestimated.Most systems rely on the patient fixing on a target ¿ usually a light in the probe.Patients with poor vision, whether from cataract or from some other pathology, are less likely to fixate accurately, and are more prone to biometry errors.Tips for accurate measurement of axial length (using applanation): ensure the machine is calibrated and set for the correct velocity setting (e.G.Cataract, aphakia, pseudophakia); the echoes from cornea, anterior lens, posterior lens, and retina should be present and of good amplitude; misalignment along the optic nerve is recognized by an absent scleral spike; the gain should be set at the lowest level at which a good reading is obtained; take care with axial alignment, especially with a hand-held probe and a moving patient (as described above); don't push too hard ¿ corneal compression commonly causes errors; errors may arise from an insufficient or greasy corneal meniscus due to ointment or methylcellulose used previously.Extremely dense cataracts create difficulties, as they absorb sound as it passes through the lens.A higher gain setting may be necessary to achieve adequate spikes.Posterior staphylomata in myopic eyes not only cause an elongated globe, but often tilt the macula as well so that the ultrasound beam is deflected.There are known reasons for biometry errors include: people in a hurry, lack of training or accessible guidelines, reliance on others, technical failure (rarely), and human error (often).Some common mistakes that may result in unexpected refractive outcome include: wrong a-constant selected, wrong formula used, wrong k-readings entered by hand (90 degrees out), biometry print-out stuck in wrong patient's notes, wrong patient in theatre, reversed iol optic, or wrong iol implanted.The operators manual includes the warning: ensure that the correct technique (contact or immersion) is selected for the technique being performed.Incorrect technique selection will impact the accuracy of the results.Contact - in the contact technique, readings are obtained by placing the biometry probe directly on the patient¿s cornea.Immersion - in the immersion technique, an immersion shell containing the probe is placed on the patient's eye and filled with solution between the probe and the cornea.Since the probe is not touching the cornea, there is an offset on the display between the peak from the probe tip and the peak from the cornea.¿ the system was examined and the reported event was not replicated.The system was tested and found to meet product specifications.A review of the customer¿s complaint history for the last 24 months did not show any previous complaints of this kind against the system.The system was manufactured on february 2, 2010.Based on qa assessment, the product met specifications at the time of release.The system was found to meet specifications.Therefore, the root cause of the reported event cannot be determined conclusively.(b)(4).
 
Event Description
Additional information has been received.The surgeon indicated the amount of the deviation was about 0.50 diopters which is so low that it could be considered normal.Patient information is not available.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
OCUSCAN RXP OPHTHALMIC ULTRASOUND SYSTEM
Type of Device
SYSTEM, IMAGING, PULSED ECHO, ULTRASONIC
Manufacturer (Section D)
ALCON RESEARCH, LTD. - IRVINE TECHNOLOGY CENTER
15800 alton parkway
irvine CA 92618
Manufacturer (Section G)
ALCON RESEARCH, LTD. - IRVINE TECHNOLOGY CENTER
15800 alton parkway
irvine CA 92618
Manufacturer Contact
rita lopez
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8175514846
MDR Report Key6420319
MDR Text Key70696539
Report Number2028159-2017-01194
Device Sequence Number1
Product Code IYO
Combination Product (y/n)N
Reporter Country CodeTU
PMA/PMN Number
K844686
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 05/17/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/21/2017
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number8065741076
Other Device ID NumberASKU
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Date Manufacturer Received04/18/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured02/02/2010
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Outcome(s) Other;
-
-