AV-TEMECULA-CT OMNILINK ELITE PERIPHERAL STENT SYSTEM Back to Search Results
Device Problems Deflation Problem (1149); Difficult to Remove (1528); Folded (2630)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 03/01/2017
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The device was not returned for evaluation.However, factors that may contribute to difficulty deflating the balloon include, but are not limited to, deflation technique, contrast concentration, tortuous anatomy, loose connection with the indeflator, contamination in the inflation lumen or damage to the guide wire and/or inflation lumen.A review of the lot history record and complaint history of the reported device could not be conducted because the part and lot numbers were not provided.The investigation was unable to determine a conclusive cause for the reported difficulties.There is no indication of a product quality issue with respect to the design, manufacture, or labeling of the device.
 
Event Description
It was reported that the omnilink elite balloon was slow to deflate after stent deployment and it was difficult to pull into the sheath due to a bad rewrapping of the balloon.The balloon had to be inflated and deflated to be able to pull it into the sheath.There was no reported adverse patient effects.No additional information was provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
OMNILINK ELITE PERIPHERAL STENT SYSTEM
Type of Device
PERIPHERAL STENT SYSTEM
Manufacturer (Section D)
AV-TEMECULA-CT
abbott vascular
26531 ynez road
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR, TEMECULA, CA USA REG# 2024168
abbott vascular
26531 ynez road
temecula CA 92591 4628
Manufacturer Contact
connie speck
abbott vascular
26531 ynez road
temecula, CA 92591-4628
9519143996
MDR Report Key6427927
MDR Text Key70912963
Report Number2024168-2017-02424
Device Sequence Number1
Product Code NIO
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
P110043
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Health Professional
Remedial Action Other
Type of Report Initial
Report Date 03/23/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/23/2017
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received03/06/2017
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-