Model Number N/A
Device Problems Unstable (1667); Insufficient Information (3190)
Patient Problem No Information (3190)
Event Date 04/05/2017
Event Type  Injury  
Manufacturer Narrative
(b)(6).It is unknown if the device will be returned for analysis; however, an investigation of the reported event is in progress.Once the investigation is completed, a supplemental medwatch will be submitted.Concomitant products - unknown head, unknown cup and unknown liner.
 
Event Description
It was reported that the patient was revised due to unknown reasons.Attempts have been made and additional information on the reported event is unavailable.
 
Manufacturer Narrative
This follow-up report is being filled to relay additional information, which was unknown at the time of the initial medwatch.
 
Event Description
It was reported that the patient was revised due to instability.
 
Manufacturer Narrative
This follow-up report is being submitted to relay additional information.Additional: updated (b)(4) modular neck 12/14 neck taper use with +0 heads only (b)(4).Complaint was confirmed with return of the compatible component.The neck was returned and evaluated.The modular neck shows damage between the conical taper and elliptical taper, indicating impingement.The elliptical taper exhibits fretting/wear.Damage is too severe for dimensional analysis.Device history record (dhr) review was unable to be performed as the lot number of the device involved in the event is unknown.Root cause was unable to be determined as the necessary information to adequately investigate the reported event was not provided.A summary of the investigation has been sent to the complainant.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN STEM
Type of Device
PROSTHESIS, HIP
Manufacturer (Section D)
ZIMMER, INC.
1800 west center street
warsaw IN 46580
Manufacturer (Section G)
ZIMMER, INC.
1800 west center street
warsaw IN 46580
Manufacturer Contact
christina arnt
56 e. bell dr.
warsaw, IN 46582
5745273773
MDR Report Key6609513
MDR Text Key76590975
Report Number0001822565-2017-03796
Device Sequence Number1
Product Code LWJ
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
PNI
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date 05/25/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received06/02/2017
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Physician
Device Model NumberN/A
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received05/23/2018
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Removal/Correction NumberN/A
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Required Intervention;
-
-