Catalog Number 190713
Device Problems Fluid/Blood Leak (1250); Split (2537)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 08/16/2017
Event Type  malfunction  
Manufacturer Narrative
The plant investigation is in process.A supplemental mdr will be submitted upon completion of this activity.
 
Event Description
A biomedical technician (biomed) at a user facility reported that the 2008t hemodialysis (hd) machine had a split in the dialysate line where the metal clamp clamps on at the back of the machine causing the dialysate to leak.The patient's blood also appeared to be hemolyzed.This was noted four (4) minutes into treatment.The patient's blood was not returned.The estimated blood loss (ebl) was 150 cc (cubic centimeters).The patient was able to complete treatment on another machine with a new set-up.There was no patient adverse effects and no medical intervention required as a result of this event.The patients post treatment condition was fine.The biomed trimmed and reconnected the dialysate line to resolve the issue.Functional testing performed by the biomed confirmed that the unit was operating properly.The system has been returned to service at the user facility without issue.No parts were available to be returned to the manufacturer for evaluation.
 
Event Description
The estimated blood loss (ebl) was 300 cc (cubic centimeters).
 
Manufacturer Narrative
The device was not returned to the manufacturer for physical evaluation.Additionally, no on-site evaluation of the unit was performed by a fresenius regional equipment specialist (res) and no parts were returned for failure analysis.The biomedical technician trimmed and reconnected the tubing to resolve the issue.Following the service activity, the system was restored to full functionality.Functional testing performed by the biomed confirmed the unit was operating properly.The unit has been returned to service at the user facility without a recurrence of the event as reported.A records review was performed on the reported serial number.An investigation of the device manufacturing records was conducted by the manufacturer.There were no deviations or non-conformance's during the manufacturing process which could be associated with the reported event.In addition, the device history record (dhr) review confirmed the results of the in-progress and final quality control (qc) testing met all requirements.A definitive conclusion regarding the complaint incident cannot be reached without a physical examination of the complaint device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
2008T HEMODIALYSIS SYS., WITH CDX
Type of Device
DIALYZER, HIGH PERMEABILITY WITH OR WITHOUT SEALED DIALYSATE SYSTEM
Manufacturer (Section D)
CONCORD MANUFACTURING
4040 nelson avenue
concord CA 94520
Manufacturer (Section G)
CONCORD MANUFACTURING
4040 nelson avenue
concord CA 94520
Manufacturer Contact
thomas c. johnson
920 winter st.
waltham, MA 02451
7816999499
MDR Report Key6854525
MDR Text Key85620929
Report Number2937457-2017-00862
Device Sequence Number1
Product Code KDI
UDI-Device Identifier00840861100897
UDI-Public00840861100897
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K093902
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,health professional
Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup,Followup
Report Date 09/21/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/11/2017
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Nurse
Device Catalogue Number190713
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Device AgeMO
Date Manufacturer Received09/18/2017
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured03/28/2012
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Age69 YR
Patient Weight67
-
-