Catalog Number UNK HIP FEMORAL STEM |
Device Problems
Metal Shedding Debris (1804); Appropriate Term/Code Not Available (3191)
|
Patient Problems
Pain (1994); Tissue Damage (2104)
|
Event Date 10/18/2017 |
Event Type
Injury
|
Manufacturer Narrative
|
If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Complete product detail has not been received at this time.If further information is received a follow-up medwatch will be filed as appropriate.
|
|
Event Description
|
The patient was revised to address pain, pseudo cyst and metal ion disease.
|
|
Manufacturer Narrative
|
No device associated with this report was received for examination.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Depuy considers the investigation closed.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Manufacturer Narrative
|
Depuy synthes is submitting this report pursuant to the provision of 21 cfr, part 803.The report may be based on the information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Product complaint # (b)(4).Investigation summary: no device associated with this report was received for examination.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Depuy considers the investigation closed.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.Device history lot : null.Device history batch : null.Device history review : null.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Event Description
|
Complaint description: the patient was revised to address pain, pseudo cyst and metal ion disease.Investigation method: no device(s) associated with this report was received for examination.In order to determine if a lot related issue was possible, a worldwide complaint database search was performed.A complaint database search did find additional related reports against the metal liner product code and lot number combination.However; a review of the device history record(s) associated with this complaint was not required per wi-3430.A worldwide complaint database search found no additional related reports against the femoral head product code/lot code combination.Based on the inability to find any additional related reports against the provided product code/lot code combination(s) it is reasonable to conclude that there are no anomalies with regard to manufacturing or inspection contained in the device history records that would contribute to the reported event.Product/lot information for the associated femoral stem is not known.The reported event is considered one of the possible complications of joint replacement.Investigational inputs were requested as indicated per internal procedures for this failure mode.The complaint information provided has been reviewed for complaint coding, medical device reporting, and other data required by the complaint system.Follow-up for additional event information was conducted, as applicable, utilizing work instruction wi-7915 appendix a.Without the physical complaint sample(s) associated with this report, it was not possible to determine if the device(s) failed to meet specification(s) at the time it was released for distribution.The device(s) associated with this event were used in the treatment of the patient as prescribed by the presiding surgeon.From the event information received, it was not possible to determine the relationship of the device to the reported event./ | investigation summary: the patient was revised to address pain, pseudo cyst and metal ion disease.Doi: dec 11, 2009; dor: oct 18, 2017; right hip.No device associated with this report was received for examination.Based on previous investigations this complication of joint replacement is unlikely to have been the result of a device failing to meet required specifications.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Corrective action was not indicated.
|
|
Search Alerts/Recalls
|
|
|