Catalog Number LSM1350837 |
Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problems
Embolus (1830); Occlusion (1984); Stenosis (2263); Ambulation Difficulties (2544)
|
Event Date 03/14/2017 |
Event Type
Injury
|
Manufacturer Narrative
|
The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.Receipt of device is not expected.The investigation is currently in progress.
|
|
Event Description
|
It was reported that there was restenosis.The complaint device was implanted (b)(6) 2015.The stent was implanted in the proximal left common iliac artery.The patient presented with instent restenosis with thrombotic occlusion in the left common iliac artery.The restenosis was treated with pta and rotarex thrombectomy and an advanta covered stent was implanted.Successful recanalization was completed on (b)(6).The patient had re-intervention again in (b)(6) 2018.On (b)(6) the patient presented with walking impairment and an embolization in the left foot.Diagnostics showed a restenosis in the left common iliac artery.A surgical bypass was created from the aorta to the left external iliac artery on the (b)(6).The patient also had treatment for re-occlusion in the right common iliac artery.The patient recovered and was discharged (b)(6).There was no patient injury reported.
|
|
Manufacturer Narrative
|
It was reported that there was restenosis.The complaint device was implanted (b)(6) 2015.The stent was implanted in the proximal left common iliac artery.The patient presented with instent restenosis with thrombotic occlusion in the left common iliac artery.The restenosis was treated with pta and rotarex thrombectomy and an advanta covered stent was implanted.Successful recanalization was completed on (b)(6).The patient had re-intervention again in (b)(6) 2018.On (b)(6) the patient presented with walking impairment and an embolization in the left foot.Diagnostics showed a restenosis in the left common iliac artery.A surgical bypass was created from the aorta to the left external iliac artery on the (b)(6).The patient also had treatment for re-occlusion in the right common iliac artery.The patient recovered and was discharged (b)(6).There was no patient injury reported.The lot history records have been reviewed with special attention to the manufacturing and inspection of this product.The device was found to have met specifications prior to shipment.No manufacturing anomalies were identified that may have caused or contributed to the reported event.This is the fourth reported complaint for this lot number and issue to date.For two of the other three complaints received the results of the investigations were inconclusive and the result of the investigation for the remaining complaint was confirmed.For this complaint the device was not returned for evaluation.The result of the investigation is confirmed.The sample was not returned for evaluation.Based upon the available information a definitive root cause cannot be determined.It also cannot be proven if the complaint stent originally implanted triggered the restenosis.It is also unknown whether patient factors, handling or procedural techniques contributed to the reported event.Based on analysis performed no additional action is required at this time.(b)(4).The ifu states: a device description 1.Implant the lifestream¿ balloon expandable vascular covered stent is comprised of an electropolished balloon-expandable stent made from 316l stainless steel, encapsulated between two layers of eptfe.B indication for use: the lifestream¿ balloon expandable vascular covered stent is indicated for the treatment of atherosclerotic lesions in common and external iliac arteries.Directions for use; site access and preparation; 1.Using standard techniques access the artery and place an introducer sheath or guiding catheter of appropriate inner diameter and a 0.035" (0.89 mm) guidewire across the target lesion.2.Perform diagnostic angiography to confirm site of implantation and measure the reference vessel diameter and lesion length.Covered stent size selection 3.Select a covered stent diameter that is approximately 5%-20% larger than the largest reference vessel diameter at the proximal or distal target site.Refer to the sizing table on the packaging label for appropriate selection of the covered stent diameter and length.Endovascular system preparation 4.Carefully remove the selected device from the package.5.Inspect the covered stent for adherence to the balloon and centered placement in relation to the balloon marker bands.If the covered stent is not centered and/or does not firmly adhere to the balloon, do not use.6.Flush the delivery system guidewire lumen with sterile saline mixture until saline drops from the distal end of the endovascular system.Air evacuation 7.A 20 cc or smaller luer-lock syringe with a minimum of 5 cc¿s sterile saline mixture is recommended for use for aspirating this device.8.With the distal balloon tip pointing down and positioned below the level of the syringe, pull negative pressure until all air is expelled.9.Induce a negative pressure to remove any air from the balloon and inflation lumen.Repeat until all air is expelled.10.Carefully release to neutral.Allow the inflation lumen to fill with the diluted contrast medium and maintain a neutral pressure.Important: do not apply positive pressure to the balloon.11.Attach the prefilled inflation device to the inflation lumen of the catheter hub, ensuring no air bubbles remain at the catheter connection.12.Verify that the covered stent is still centered between the two radiopaque markers on the balloon catheter.Introduction of the endovascular system and placement of the covered stent 13.Advance the endovascular system over the guidewire into the introducer sheath.14.Further advance the endovascular system to the target treatment site within the introducer sheath and position the covered stent across the lesion.Verify that the covered stent is still centered within the balloon marker bands.Slowly retract the introducer sheath / guiding catheter while maintaining the position of the covered stent.Ensure the introducer sheath is retracted far enough to not compromise the balloon expansion and covered stent release.(b)(4).
|
|
Search Alerts/Recalls
|