Model Number 164267
Device Problems Corroded (1131); Device Displays Incorrect Message (2591)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 01/25/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(4).
 
Event Description
It was reported that prior to use of the device for cardiopulmonary bypass (cpb) procedure, an "overspeed" error message was displayed.As a result, an alternate device was employed.The surgical procedure was completed successfully.There was no delay, no blood loss, nor adverse consequences to the patient.Per clinical review: during set up for a procedure on (b)(6) 2018, the perfusionist had an "overspeed" error on the heart lung machine (hlm).She checked to make sure that the disposable was seated correctly on the centrifugal motor, and checked all connections in the system, and all were in working order.The team changed out the hlm, and prepared to use another system for the procedure.The procedure was not delayed due to the overspeed error.There was no harm nor associated blood loss due to the issue.
 
Manufacturer Narrative
The reported complaint was confirmed.The returned motor assembly was determined to be not defective since it passed all the evaluations needed.However, the corrosions were seen in the motor controller pins of the associated complaint which then resulted to the reported issue.If additional information becomes available on this complaint that would alter the facts and/or conclusion, a supplemental report will be filed accordingly.This complaint is related to (b)(4) / medwatch #1828100-2018-00090.
 
Manufacturer Narrative
During laboratory analysis, the product surveillance technician (pst) observed the pump to function as intended throughout the evaluation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADVANCED PERFUSION SYSTEM 1
Type of Device
CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS-ADVANCED PERFUSION SYSTEM 1
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORPORATION
6200 jackson road
ann arbor MI 48103
MDR Report Key7280600
MDR Text Key100557701
Report Number1828100-2018-00082
Device Sequence Number1
Product Code DTQ
Combination Product (y/n)N
PMA/PMN Number
K163531
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional,user faci
Type of Report Initial,Followup,Followup,Followup
Report Date 05/24/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/19/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number164267
Device Catalogue Number164267
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/22/2018
Was the Report Sent to FDA? No
Date Manufacturer Received05/08/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-