CPI - DEL CARIBE INGEVITY; IMPLANTABLE LEAD Back to Search Results
Model Number 7741
Device Problems Capturing Problem (2891); Device Contamination With Biological Material (2908); Material Integrity Problem (2978)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 03/30/2018
Event Type  malfunction  
Manufacturer Narrative
At this time, the product has not been returned.If the product is returned, analysis will be performed and this report would be updated at that time.
 
Event Description
Boston scientific received information that when implanting this right ventricular (rv) lead the helix was extended, but the pacing thresholds were high thus the lead was repositioned two times.The helix was extended a third time but the lead had dislodged.The helix was then attempted to be retracted, but it was not possible to retract.When the rv lead was removed tissue was seen in the helix mechanism, thus a new lead was used with no issues.This rv lead will be returned.No adverse patient effects were reported.
 
Manufacturer Narrative
This lead was returned to boston scientific¿s post market quality assurance laboratory with the helix mechanism in an extended position.Visual inspection found dried blood/tissue around the helix.Subsequent testing did not identify any product abnormalities that may have caused or contributed to the reported clinical observations.Laboratory analysis was unable to conclusively determine the root cause of the reported helix extension/retraction problems.The lead also passed electrical testing.The ingevity mri-compatible lead was designed with a goal of balancing multiple design inputs, including implant handling and short and long term safety performance (e.G., low dislodgement and perforation occurrence).The single filar inner coil design of the ingevity lead was selected for improved fatigue durability and for safe performance within an mri environment (protective against lead heating).Physician implant technique and patient anatomy may contribute to helix extension difficulty.Specifically, tortuous patient anatomy or bends in the proximal portion of the lead remaining outside of the body, sharp bends in the stylet, and/or kinks in the lead introducer sheath may contribute to situations where adequate torque is not transferred to the helix to enable extension/retraction.Implant techniques such as under-rotating or over-rotating the terminal tool, failure to remove the terminal tool between extension/retraction cycles to release torque stored in the inner coil, excessively fast tool rotation speed (>1 full turn per second), and the presence of tissue in the helix, which may accumulate with multiple lead repositioning attempts may also contribute to situations where adequate torque is not transferred to the helix to enable extension/retraction.Approved instructions for use provided with all products includes best practices and clear guidance to mitigate these potential contributing factors.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INGEVITY
Type of Device
IMPLANTABLE LEAD
Manufacturer (Section D)
CPI - DEL CARIBE
guidant puerto rico b. v.
dorado PR
Manufacturer (Section G)
CPI - DEL CARIBE
guidant puerto rico b. v.
dorado PR
Manufacturer Contact
tim degroot
4100 hamline ave. n
st. paul, MN 
6515826168
MDR Report Key7436532
MDR Text Key105685443
Report Number2124215-2018-07003
Device Sequence Number1
Product Code LWP
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 05/08/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/17/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date02/21/2020
Device Model Number7741
Other Device ID NumberINGEVITY MRI
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/23/2018
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? Yes
Date Manufacturer Received05/08/2018
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured02/21/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
7741; L310
Patient Age90 YR
-
-