Catalog Number 381223
Device Problems Detachment Of Device Component (1104); Component Falling (1105); Device Operates Differently Than Expected (2913)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 02/26/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(6).Investigation conclusion: samples/ photos: according to the visual analysis of the photo containing the claimed sample, it was possible to identify that the component (filter plug) was loose inside the package of product.Dhr review: the insyte assembled in icam #02 in the period between 04 and (b)(6) 2017, lot: 7087519, used in the final product lot: 7118890 of insyte 22g 1,00 was analyzed regarding the test of "loose filter plug" and were not evidenced records that could lead to the claimed defect.However, a note dated (b)(6) 2017 was noted which describes: "broken claw spring, station # 18, track #1, chassis # 2" that may have led to this complaint.The packaged lot: 7118890 was manufactured in r530-2 machine on (b)(6) 2017 and no records of "missing component" were evidenced.Qn/ ncmr review: there are no quality notification (qn) or nonconformity report of "loosen filter plug¿ or something that could lead to this complaint.Unplanned maintenance: during the investigation, the history of corrective maintenance during the assembly period of the batch involved in this claim was evaluated.As a result of this analysis, corrective maintenance record #(b)(6) was performed on (b)(6) 2017 for the following reason: "broken spring of the claw est-18 track-1 # 2" that might have led to the incident in question root cause description: our quality engineer was able to verify the component (filter plug) was loose inside the package of product.The root cause for the issue is due to the breaking of the claw of a machine which led to poor placement of the plug in the hub.A corrective action was performed by changing the spring and adjusting the claw position.
 
Event Description
It was reported that before use a bd insyte¿ peripheral venous catheter malfunctioned as "after opening, the plastic tip came off and fell." there was no report of exposure, injury or medical intervention needed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD INSYTE¿ PERIPHERAL VENOUS CATHETER
Type of Device
INTRAVASCULAR CATHETER
Manufacturer (Section D)
BECTON DICKINSON INDUSTRIAS CIRURGICAS, LTDA.
ave. pres.juscelino kubitschek
273 francisco bernardino
juiz de fora
Manufacturer (Section G)
BECTON DICKINSON INDUSTRIAS CIRURGICAS, LTDA.
ave. pres.juscelino kubitschek
273 francisco bernardino
juiz de fora
Manufacturer Contact
brett wilko
9450 south state street
sandy, UT 84070
8015652845
MDR Report Key7477896
MDR Text Key107600213
Report Number9610048-2018-00056
Device Sequence Number1
Product Code FOZ
UDI-Device Identifier30382903812234
UDI-Public30382903812234
Combination Product (y/n)N
Reporter Country CodeCA
PMA/PMN Number
K151698
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor,foreign,health pr
Reporter Occupation Health Professional
Type of Report Initial
Report Date 04/30/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received05/01/2018
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Other
Device Expiration Date04/30/2022
Device Catalogue Number381223
Device Lot Number7118890
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received03/13/2018
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured05/16/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
-
-