MAUDE Adverse Event Report: ARROW INTERNATIONAL INC. EPIDURAL CATHETERIZATION SET; ANESTHESIA CONDUCTION KIT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARROW INTERNATIONAL INC. EPIDURAL CATHETERIZATION SET; ANESTHESIA CONDUCTION KIT Back to Search Results
Catalog Number JC-05400-B
Device Problem Physical Resistance (2578)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 04/01/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The device has not been returned for investigation.Teleflex will continue to monitor and trend related events.
 
Event Description
It was reported that during insertion, the plunger of the syringe had a lack of resistance.There was no reported patient injury.
 
Manufacturer Narrative
(b)(4).A device history record review was performed on the lor syringe with no relevant findings.The customer reported there was a lack of resistance with the lor syringe.The customer returned one 10ml plastic lor syringe and lidstock (reference attached files (b)(4).The syringe was visually examined with and without magnification.Visual examination of the syringe revealed that the syringe appears typical with no observed defects or anomalies.Functional testing was performed on the returned syringe using the lab leak tester (c05176) per the parameters in amrq-000155 rev.4, section 7.2-positive pressure leakage.Water was aspirated into the syringe to the 8ml mark and the syringe was inverted to remove any air from the barrel.The tip of the syringe was then connected to the lab leak tester via tubing and pressure was applied.The syringe was tested at 10psi for 10 seconds.No leaks were detected.Water was removed from the syringe to the 2ml mark and the syringe was inverted to remove any air from the barrel.The tip of the syringe was then connected to the lab leak tester via tubing and pressure was applied.The syringe was tested at 10psi for 10 seconds.No leaks were detected.The other remarks: returned lor syringe was compared to a lab inventory syringe by sliding the plunger into the barrel of the syringe.The resistance of the returned lor syringe was comparable to the lab inventory syringe.The luer end of the returned syringe was capped with the plunger completely inserted.An attempt to remove the plunger from the barrel was performed.The plunger seal snapped back when attempting to remove from the barrel.This was also performed with a lab inventory syringe with the same results.This indicates the plunger seal was creating a vacuum with no issues.The reported complaint of the lor syringe had a lack of resistance could not be confirmed based on the sample received.The returned lor syringe passed functional testing including a leak test.Also, the returned lor syringe when compared to a lab inventory syringe had comparable resistance when sliding the plunger into the barrel of the syringe.A device history record review was performed on the lor syringe with no evidence to suggest a manufacturing related issue.There were no functional issues found with the returned sample.(b)(4).
 
Event Description
It was reported that during insertion, the plunger of the syringe had a lack of resistance.There was no reported patient injury.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EPIDURAL CATHETERIZATION SET
Type of Device
ANESTHESIA CONDUCTION KIT
Manufacturer (Section D)
ARROW INTERNATIONAL INC.
reading PA
Manufacturer (Section G)
ARROW INTERNATIONAL CR, A.S.
jamska 2359/47
zdar nad sazavou 591 0 1
EZ   591 01
Manufacturer Contact
jasmine brown
3015 carrington mill blvd
morrisville, NC 27560
9193614124
MDR Report Key7500632
MDR Text Key107828375
Report Number3006425876-2018-00302
Device Sequence Number1
Product Code CAZ
Combination Product (y/n)N
Reporter Country CodeFR
PMA/PMN Number
K103658
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 05/04/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received05/09/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date02/18/2020
Device Catalogue NumberJC-05400-B
Device Lot Number71F18B1449
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/05/2018
Is the Reporter a Health Professional? Yes
Date Manufacturer Received06/20/2018
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured02/13/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage N
Patient Sequence Number1
-
-