Model Number M0068318150
Device Problem Detachment Of Device Component (1104)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 04/25/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The device has been received for analysis.Upon completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental medwatch will be filed.
 
Event Description
It was reported to boston scientific corporation that a pinnacle¿ lite with capio slim was used during a pinnacle lite procedure performed on (b)(6) 2018.According to the complainant, during the procedure, the dart detached from the suture upon pulling the mesh arm through the sacrospinous ligament on the right side of the patient.Reportedly, the dart was found in the capio cage and was not left in the patient.The procedure was completed with another pinnacle¿ lite with capio slim.The patient's condition at the conclusion of the procedure was reported to be stable.
 
Manufacturer Narrative
Analysis of the returned pinnacle lite with capio slim revealed that the suture on the blue with white stripe dilator was broken.The remainder of the suture with dart was returned.Analysis also revealed no damage to the capio slim suture capturing device.There was debris inside the cage.A review of the device history record (dhr) indicated that the device met all material, assembly, and product specifications at the time of release to distribution.However, the investigation concluded that the most probable cause for this event is supplier manufacturing process design because the design or validation of a suppliers manufacturing process was not sufficient to ensure the finished device met the intent of the design.An investigation concluded that the design of the carrier allows the fiber portion of the suture to interact with the sharp edge of the carrier, resulting in suture severing.The issue is under investigation and a correction has not yet been implemented.
 
Event Description
It was reported to boston scientific corporation that a pinnacle lite with capio slim was used during a pinnacle lite procedure performed on (b)(6) 2018.According to the complainant, during the procedure, the dart detached from the suture upon pulling the mesh arm through the sacrospinous ligament on the right side of the patient.Reportedly, the dart was found in the capio cage and was not left in the patient.The procedure was completed with another pinnacle lite with capio slim.The patient's condition at the conclusion of the procedure was reported to be stable.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PINNACLE¿ LITE
Type of Device
MESH, SURGICAL, SYNTHETIC, UROGYNECOLOGIC, FOR PELVIC ORGAN PROLAPSE, TRANSVAGIN
Manufacturer (Section D)
BOSTON SCIENTIFIC - MARLBOROUGH
100 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC - MARLBOROUGH
100 boston scientific way
marlborough MA 01752
Manufacturer Contact
nancy cutino
100 boston scientific way
marlborough, MA 01752
5086834000
MDR Report Key7524738
MDR Text Key108673926
Report Number3005099803-2018-01489
Device Sequence Number1
Product Code OTP
Combination Product (y/n)N
PMA/PMN Number
K122459
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 04/25/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received05/17/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date04/11/2020
Device Model NumberM0068318150
Device Lot Number0000062154
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/03/2018
Is the Reporter a Health Professional? Yes
Date Manufacturer Received06/13/2018
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured04/24/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-