Model Number N/A
Device Problems Difficult to Insert (1316); Difficult To Position (1467)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 07/05/2018
Event Type  Injury  
Manufacturer Narrative
(b)(4).Concomitant medical products: 010000665, g7 pps ltd acet shell 56f, 6242109.(b)(6).The investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Event Description
It was reported that during initial hip procedure, the liner didn¿t seat with the cup, the liner was impacted numerous times, this did not cause it to seat properly.It had to be removed with the liner extraction tool which damaged the liner.The procedure was completed with a second liner on site.
 
Manufacturer Narrative
(b)(4).Reported event was unable to be confirmed due to limited information received from the customer.Dhr was reviewed and no discrepancies were found.Root cause was unable to be determined as the necessary information to adequately investigate the reported event was not provided.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event Description
No further event information available at the time of this report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
G7 HI-WALL E1 LINER 36MM F
Type of Device
PROSTHESIS HIP
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
MDR Report Key7554277
MDR Text Key109568267
Report Number0001825034-2018-03405
Device Sequence Number1
Product Code PBI
Combination Product (y/n)N
PMA/PMN Number
PN/A
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor,foreign,health pr
Type of Report Initial,Followup
Report Date 04/17/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received05/30/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Physician
Device Expiration Date03/10/2023
Device Model NumberN/A
Device Catalogue Number010000936
Device Lot Number6250824
Other Device ID NumberN/A
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Date Manufacturer Received04/16/2019
Is This a Reprocessed and Reused Single-Use Device? No
Removal/Correction NumberN/A
Patient Sequence Number1
-
-