Catalog Number SLPL6545
Device Problem Material Protrusion/Extrusion (2979)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 10/09/2017
Event Type  Injury  
Manufacturer Narrative
Evaluation in process but not yet complete.Upon completion of evaluation, a follow up report will be submitted.
 
Event Description
It was reported that the doctor was final tightening the set screw and the threads came out of the 6.5 mm x 45 mm polyaxial screw long arm (slpl6545).He tried another locking cap and rest of threads came out so the slpl6545 was removed and replaced a slp6545 6.5 mm x 45 mm s-lok polyaxial screw.There was a 10 minute delay as a result, but no harm to patient.
 
Event Description
It was reported that the doctor was final tightening the set screw and the threads came out of the 6.5mm x 45mm polyaxial screw long arm (slpl6545).He tried another locking cap and rest of threads came out so the slpl6545 was removed and replaced a slp6545 6.5mm x 45mm s-lok polyaxial screw.There was a 10 minute delay as a result, but no harm to patient.
 
Manufacturer Narrative
Product evaluation - the root cause of the missing full thread on the slpl tulips has been attributed to the tooling off-set was not properly touched off after a tooling change for the 45 degree id tool.The lack of zeroing the tool properly resulted in the visible reduction of the thread width and the loss of the square shape of the full thread.A health hazard evaluation was performed to assess the risk of the identified non-conformance.It was determined that there was a none/negligible health risk to the patient.Review of manufacturing history record found (b)(4) pieces of lot 10913ps were released for distribution on 1/9/2017 with no deviations or anomalies.Two-year complaint history review found this to be the only report for this lot.Further review did not identify a trend for reports of this nature for this part number.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
6.5MM X 45MM POLYAXIAL SCREW LONG ARM
Type of Device
POLYAXIAL SCREW
Manufacturer (Section D)
PRECISION SPINE, INC
2050 executive drive
pearl MS 39208
MDR Report Key7639273
MDR Text Key112384017
Report Number3005739886-2018-00004
Device Sequence Number1
Product Code MNH
Combination Product (y/n)N
PMA/PMN Number
K092128
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor
Type of Report Initial,Followup
Report Date 10/09/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received06/26/2018
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Physician
Device Catalogue NumberSLPL6545
Device Lot Number10913PS
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/23/2017
Was the Report Sent to FDA? No
Date Manufacturer Received10/09/2017
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-