Model Number 7741
Device Problems Capturing Problem (2891); Device Contamination With Biological Material (2908); Device Sensing Problem (2917); Device Dislodged or Dislocated (2923); Material Integrity Problem (2978)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 06/21/2018
Event Type  malfunction  
Manufacturer Narrative
As no further information concerning this report is expected, our investigation is complete.This investigation will be updated should further information be provided.
 
Event Description
Boston scientific received information that during the implant of this right ventricular (rv) lead the physician was attempting manipulate the helix in order to fixate the lead into the heart, but the helix got entangled with myocardium from the tip of the lead and it was not possible to manipulate.The rv lead had dislodged.It was not possible to retract the helix by rotating it clockwise after more than sixty turns.The pacing thresholds and sensing amplitudes were not good thus the lead was extracted.It was noted that the helix of the rv lead was stretched and not stable.A new lead was used.This lead will not be returned due to the patient infectious disease.
 
Event Description
No adverse patient effects were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INGEVITY
Type of Device
IMPLANTABLE LEAD
Manufacturer (Section D)
CPI - DEL CARIBE
guidant puerto rico b. v.
dorado PR
Manufacturer (Section G)
CPI - DEL CARIBE
guidant puerto rico b. v.
dorado PR
Manufacturer Contact
tim degroot
4100 hamline ave. n
st. paul, MN 
6515826168
MDR Report Key7658266
MDR Text Key113013411
Report Number2124215-2018-11879
Device Sequence Number1
Product Code LWP
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 07/08/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/03/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date03/20/2020
Device Model Number7741
Other Device ID NumberINGEVITY MRI
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? Yes
Date Manufacturer Received07/08/2018
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured03/20/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
7741; 7742; L300
Patient Age84 YR
-
-