• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ZIMMER BIOMET, INC. PERSONA TM CRUCIATE RETAINING NARROW POROUS FEMORAL COMPONENT SIZE 7 LEFT; PROSTHESIS, KNEE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ZIMMER BIOMET, INC. PERSONA TM CRUCIATE RETAINING NARROW POROUS FEMORAL COMPONENT SIZE 7 LEFT; PROSTHESIS, KNEE Back to Search Results
Model Number N/A
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Respiratory Acidosis (2482); Respiratory Failure (2484)
Event Date 10/11/2016
Event Type  Injury  
Manufacturer Narrative
(b)(4).Concomitant medical devices ¿ persona cemented stemmed natural tibial component size e left catalog #: 42532007101 lot #: 63189523, persona ultracongruent vivacit-e articular surface 11 mm catalog #: 42512200511 lot #: 62335084, persona all poly patella 35 mm catalog #: 42540000035 lot #: 63432243.The complainant has indicated that the product will not be returned to zimmer biomet for investigation, as the devices remain implanted.The investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.Multiple mdr reports were filed for this event, please see associated reports: 0002648920-2018-00622, 0001822565-2018-04159, 0002648920-2018-00623.Device remains implanted.
 
Event Description
It was reported that the patient experienced status asthmaticus and was immediately admitted to an intensive care unit following knee arthroplasty to treat hypercapnia and respiratory acidosis/failure.No additional patient consequences were reported.
 
Manufacturer Narrative
The product was evaluated through manufacturing review and the reported event was confirmed through review of medical records.The device history records were reviewed and no discrepancies were identified.The reported issues are related to the procedure and not abnormal to the procedure with no failure detected with the devices.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event Description
No further event information available at the time of this report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PERSONA TM CRUCIATE RETAINING NARROW POROUS FEMORAL COMPONENT SIZE 7 LEFT
Type of Device
PROSTHESIS, KNEE
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
MDR Report Key7751417
MDR Text Key116050407
Report Number0001822565-2018-04158
Device Sequence Number1
Product Code MBH
Combination Product (y/n)N
PMA/PMN Number
PK172524
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,consum
Type of Report Initial,Followup
Report Date 07/17/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/06/2018
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model NumberN/A
Device Catalogue Number42502206201
Device Lot Number63199066
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Date Manufacturer Received07/16/2019
Is This a Reprocessed and Reused Single-Use Device? No
Removal/Correction NumberN/A
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Required Intervention;
Patient Age73 YR
Patient Weight84
-
-