ZIMMER BIOMET, INC. EXACT STEM REMOVAL JAW; PROSTHESIS, HIP Back to Search Results
Model Number N/A
Device Problem Fracture (1260)
Patient Problem No Information (3190)
Event Date 08/23/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Customer has indicated that the product will not be returned to zimmer biomet for investigation, as the product location is unknown.The investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Event Description
It was reported that the tip of the stem extractor fractured during hip revision surgery.Attempts have been made and no additional information is available.
 
Manufacturer Narrative
This follow-up report is being submitted to relay additional information.Complaint sample was evaluated and the reported event was confirmed.One exact stem removal jaw was returned and evaluated.Upon visual inspection the device has disassociated between the main body & slap hammer connector.The threaded end was fractured from the rest of the jaw and the threads are mostly sheared off.The device was sent for fracture analysis and the analysis identified the fracture artifacts suggest a tensile overload fracture of the weld & longitudinal shearing of the threads.It is unknown which fracture occurred first and was not able to be determined.The device history records were reviewed and no related deviations/ anomalies were identified that affect the reported event.A definitive root cause could not be determined.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event Description
No further event information available at the time of this report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EXACT STEM REMOVAL JAW
Type of Device
PROSTHESIS, HIP
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
MDR Report Key7902520
MDR Text Key121564673
Report Number0001825034-2018-09085
Device Sequence Number1
Product Code HWB
Combination Product (y/n)N
PMA/PMN Number
PEXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor,health profession
Type of Report Initial,Followup
Report Date 02/04/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/24/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberN/A
Device Catalogue NumberX31-400060
Device Lot Number475832
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/05/2018
Was the Report Sent to FDA? No
Date Manufacturer Received02/04/2019
Is This a Reprocessed and Reused Single-Use Device? No
Removal/Correction NumberN/A
Patient Sequence Number1
-
-