EDWARDS LIFESCIENCES DR PRESSURE MONITORING KIT WITH TRUWAVE DISPOSABLE PRESSURE TRANSDUCER AND VAMP JR.; TRANSDUCER, PRESSURE, CATHETER TIP Back to Search Results
Model Number VMP306
Device Problems Crack (1135); Fluid/Blood Leak (1250); Leak/Splash (1354); Obstruction of Flow (2423)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 10/08/2018
Event Type  malfunction  
Manufacturer Narrative
One vamp jr.System and a 10ml syringe was returned for examination.The reported event of "leaking" was confirmed.Leakage was detected at the bond joint between the pressure tubing to reservoir stopcock.Red dye solution was manually injected into the vamp system to trace the leak path.Leakage was found occurring across the bond area.No visible damage was observed from the pressure tubing and reservoir stopcock.Lot number was not provided, therefore review of the manufacturing records could not be completed.An investigation has been initiated to consider any potential manufacturing factors that may have contributed to this complaint and implement any necessary corrective actions.Invasive procedures involve some patient risks.Although serious complications are relatively uncommon, the physician is advised to consider the potential benefits in relation to the possible complications.It is common clinical practice to inspect all products before use.These products are used by highly trained clinicians, experienced in identifying and mitigating any hazards that arise during use.In addition, these devices are typically used in intensive care units or operating rooms, where patients are closely monitored.Tubing breakage will most likely occur during handling and manipulation of the product and will result in an obvious leak prior to connecting to the patient or during tightening of connections during use.Therefore, the break in the system will be immediately detected.Since these devices are indicated for pediatric patients, whose blood volume is much smaller than an adult, they cannot tolerate blood loss as easily as adults.Consequently, there is potential for patient injury.In this case, there were no patient complications noted.Complaint histories for all reported events are reviewed against trending control limits on a monthly basis, and any excursions above the control limits are assessed and documented as part of this monthly review.
 
Event Description
It was reported that while using a vamp jr, blood was backing up into the arterial line.The connections were checked and the staff increased the rate the fluid that was infusing, with no success.(what fluid they increased is unknown.) it was then noticed that there was a crack on the vamp connection piece near the port and the medication papaverine was leaking from the crack.No patient complications were reported.Patient demographics unavailable.To date, additional information requests have been made without success.
 
Manufacturer Narrative
The investigation of this pressure monitoring kit with vamp jr concluded that a potential root cause of leakage at the bond joint between pressure tubing to reservoir stopcock could be related to an incorrect solvent bonding execution during the assembly process.Personnel acknowledgement was conducted at the manufacturing site to prevent recurrence of this type of complaint.
 
Manufacturer Narrative
Reference capa-20-00141.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PRESSURE MONITORING KIT WITH TRUWAVE DISPOSABLE PRESSURE TRANSDUCER AND VAMP JR.
Type of Device
TRANSDUCER, PRESSURE, CATHETER TIP
Manufacturer (Section D)
EDWARDS LIFESCIENCES DR
parque industrial de itabo
carr. sanchez km 18.5
haina, san cristobal
DR 
MDR Report Key8040130
MDR Text Key127372053
Report Number2015691-2018-04539
Device Sequence Number1
Product Code DXO
Combination Product (y/n)N
PMA/PMN Number
K925638
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup,Followup
Report Date 10/12/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/05/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberVMP306
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/29/2018
Date Manufacturer Received07/23/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-