• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION INTELLAMAP ORION HIGH RESOLUTION MAPPING CATHETER; CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION INTELLAMAP ORION HIGH RESOLUTION MAPPING CATHETER; CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING Back to Search Results
Model Number M004RC64S0
Device Problems Electrical /Electronic Property Problem (1198); Poor Quality Image (1408); Defective Device (2588)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 08/30/2018
Event Type  malfunction  
Manufacturer Narrative
Age at time of event: 18 years or older.
 
Event Description
It was reported that electrodes became inactive.A intellamap orion catheter was used in a procedure.However during the case, 13 electrodes got became inactive and mapping was unable to performed.The issue was resolved after replacing the catheter with another orion catheter.No patient complications were reported.However, returned device analysis revealed corrosion on the electrodes.Visual inspection shows the deployment shaft is bent.The electrical test was performed and the device failed the test.Magnetic sensor resistance and inductance testing revealed both pairs are within specification.The device is seen to have organic damage caused by normal use of the device over a prolonged period.The device also has a gap between the red and white collars of the proximal side of the array.The gap seen allowed fluid to contact the traces and corrosion present diminished the ability for the electrodes to function.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INTELLAMAP ORION HIGH RESOLUTION MAPPING CATHETER
Type of Device
CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
Manufacturer (Section G)
BOSTON SCIENTIFIC DE COSTA RICA S.R.L.
302 parkway
global park, la aurora,
heredia
CS  
Manufacturer Contact
timothy degroot
4100 hamline avenue north
dc a330,
saint paul, MN 55112
6515826168
MDR Report Key8184095
MDR Text Key131000335
Report Number2134265-2018-64563
Device Sequence Number1
Product Code DRF
UDI-Device Identifier08714729841968
UDI-Public08714729841968
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
K143481
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Physician
Type of Report Initial
Report Date 12/20/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/20/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date01/23/2019
Device Model NumberM004RC64S0
Device Catalogue Number87035
Device Lot Number0021648493
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/17/2018
Is the Reporter a Health Professional? Yes
Date Manufacturer Received11/28/2018
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured01/23/2018
Is the Device Single Use? Yes
Type of Device Usage N
Patient Sequence Number1
-
-