• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: TERUMO CORPORATION IMUFLEX BLOOD BAG SYSTEM; IMUFLEX WB-RP BLOOD BAG SYSTEM WITH LR FILTER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TERUMO CORPORATION IMUFLEX BLOOD BAG SYSTEM; IMUFLEX WB-RP BLOOD BAG SYSTEM WITH LR FILTER Back to Search Results
Catalog Number 1BBWGQ506A2
Device Problems Restricted Flow rate (1248); Incorrect, Inadequate or Imprecise Result or Readings (1535); Defective Component (2292); Filtration Problem (2941)
Patient Problem No Patient Involvement (2645)
Event Date 01/16/2019
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Investigation is in process.A follow up report will be provided.
 
Event Description
The customer reported elevated white blood cell (wbc) content in a filtered whole blood unit.There was not a transfusion recipient or patient involved at the time of whole blood processing, therefore no patient information is reasonably known at the time of the event.Donor unit #: (b)(6).
 
Manufacturer Narrative
Investigation: one set of blood bags with the filter from the collection set was returned for evaluation.The leukoreduction filter was tested for flow rate and air leaks.A very swift flow rate of 135ml/min was noted, and it was confirmed there were no air leaks.The filter was disassembled to observe the appearance of filter membranes and noticed creases in the filter membranes of the filter.The creases in the filter were not different from those inconforming products and no aggregation was observed in any filter membranes.The manufacturing records, test records, and inspection records were reviewed for abnormalities and none were found.The records regarding the particulate removal rates of the filter membranes were reviewed.All membranes conformed to established specification.Shipping testing was performed on the reserve samples from the reported lot number.The reserve samples were also visually examined, and the solution volume and solution composition were tested with no abnormalities noted.All product conformed to the established specification.Root cause: based on the available information, it cannot be ruled out that the higher-than-expected wbc content in the whole blood product could be due to an occlusion, we noticed that the fifth and sixth filter membranes from the inflow side of the filter were locally dyeddark with toluidine blue.The investigation showed no aggregation on any of the filter membranes.Therefore, occlusion may have occurred, and blood may have been filtered by the filter area which was smaller than usual and the linear speed (flow rate per unit area) increased,and then leukocyte leakage occurred.As an increase of wbc contamination complaints were noted from previous lot numbers, further investigation was performed.Investigation results indicated that the cause of higher-than-expected wbc content in the whole blood product was due to the maximum pore size of the filter membrane is likely to increase according to the combination of multiple parameters in manufacture of leukoreduction filter membranes and wbc contamination is likely to occur frequently in the product lots of which the maximum poresize of the filter membrane has increased.The instructions for use provide a caution to not squeeze or apply pressure to the filter while it is attached to the bag containing the filtered blood and also to clamp the blood-filled tubing before blood enters the filter in order to avoid leukocyte leakage.Corrective action: an internal capa has been initiated to review the maximum pore size of the filter membrane and the likelihood of an increase according to the combination of the multiple parameters.In addition, the wbc contamination is likely to occur frequently in the product lots of which the maximum pore size of the filter membrane has increased.To achieve a resolution, manufacturing specifications were updated to narrow the range of the parameters in the manufacture of filter membranes and it was confirmed that the appropriate level of the maximum pore size of the filter membrane was achieved.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
IMUFLEX BLOOD BAG SYSTEM
Type of Device
IMUFLEX WB-RP BLOOD BAG SYSTEM WITH LR FILTER
Manufacturer (Section D)
TERUMO CORPORATION
fujinomiya
MDR Report Key8331867
MDR Text Key137025502
Report Number9681839-2019-00012
Device Sequence Number1
Product Code KSR
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Type of Report Initial,Followup
Report Date 02/12/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/12/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date07/31/2020
Device Catalogue Number1BBWGQ506A2
Device Lot Number180219KK
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/25/2019
Was the Report Sent to FDA? Yes
Distributor Facility Aware Date01/18/2019
Device Age12 MO
Event Location Hospital
Date Report to Manufacturer02/12/2019
Date Manufacturer Received03/04/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Other;
-
-