MAUDE Adverse Event Report: OBERDORF SYNTHES PRODUKTIONS GMBH; ORTHOSIS, SPONDYLOSTHESIS SPINAL FIXATION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

OBERDORF SYNTHES PRODUKTIONS GMBH; ORTHOSIS, SPONDYLOSTHESIS SPINAL FIXATION Back to Search Results
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Discomfort (2330); No Code Available (3191)
Event Date 01/10/2018
Event Type  Injury  
Manufacturer Narrative
This report is for an unknown constructs: uss ii/unknown lot.Part and lot number are unknown; udi number is unknown.Complainant part is not expected to be returned for manufacturer review/investigation.(b)(4).The reported event required medical/surgical intervention to preclude permanent damage to a body structure.Investigation summary product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.(b)(4).
 
Event Description
Device report from synthes reports an event in japan as follows: this report is being filed after the review of the following journal article: futamura k et al (2018), ¿within ring¿-based sacroiliac rod fixation may overcome the weakness of spinopelvic fixation for unstable pelvic ring injuries: technical notes and clinical outcomes.International orthopaedics.Volume 42.Pages 1405-1411.(japan).The objective of this study was to explain the surgical procedure of ¿within ring¿-based sacroiliac rod fixation (sirf) and present clinical outcomes.Between january 2012 and december 2016, 15 patients with pelvic ring fracture treated with sacroiliac rod fixation were included in the study.There were 10 male and 5 females with a mean age of 49.5 years old (range, 20-83 years old).Patients were implanted with an unknown synthes universal spine system ii (uss ii) ilio-sacral, modular system with universal spine system ii dual-core cancellous polyaxial screws.The mean follow-up period was 23.8 months (4¿50 months), and bone union was achieved in all patients.3 patients were loss to follow-up.Complications were reported as follows: an (b)(6) year-old male patient died during hospitalization.A (b)(6) year-old male patient had a deep infection and was treated with lavage and debridement.In fig.2 (d), 1 patient had a right s1 pedicle screw that was directed too medially that the screw deviated into the spinal canal.The patient complained of numbness of the s1 region after surgery.Implant removal was scheduled soon after bone union.The article mentioned 3 patients who had implant removal within 1 year after surgery; 2 due to implant irritation and 1 by patient request.Table 1 identified the following 3 patients who had implant removal, however, the reason for each implant removal was not specified: a (b)(6) year-old male patient had implant removal.A (b)(6) year-old male patient had implant removal.A (b)(6) year-old female patient had implant removal.This report is for one (1) device- an unknown synthes universal spine system ii.This is report 5 of 5 for (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Type of Device
ORTHOSIS, SPONDYLOSTHESIS SPINAL FIXATION
Manufacturer (Section D)
OBERDORF SYNTHES PRODUKTIONS GMBH
eimattstrasse 3
oberdorf 4436
SZ  4436
Manufacturer Contact
kara ditty-bovard
eimattstrasse 3
oberdorf 4436
SZ   4436
6103142063
MDR Report Key8501617
MDR Text Key141577353
Report Number8030965-2019-62685
Device Sequence Number1
Product Code MNH
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,literature,study
Reporter Occupation Other
Type of Report Initial
Report Date 03/18/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/10/2019
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Was Device Available for Evaluation? No
Date Manufacturer Received03/18/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Type of Device Usage Unknown
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-