Catalog Number 03.010.103
Device Problem Material Split, Cut or Torn (4008)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 04/10/2019
Event Type  malfunction  
Manufacturer Narrative
Complainant part is expected to be returned for manufacturer review/investigation, but has yet to be received.The investigation could not be completed; no conclusion could be drawn at the time of filing this report.A review of the device history records has been requested.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
Device report from synthes reports an event in (b)(6) as follows: it was reported that on (b)(6) 2019, a patient underwent an open reduction internal fixation (orif) with the multiloc humeral nailing system for a proximal humeral diaphyseal fracture.During the surgery, it seemed that the drill bit was dull, the surgeon managed to drill for two (2) unknown screws.However, when the surgeon was drilling for the third unknown screw, the drill bit did not move forward after scraping the cortical bone.It was then that the surgeon used another drill bit and completed the drilling without any difficulty.There was no reported surgical delay.The procedure was completed with no adverse consequence to the patient.Concomitant device reported: unknown screws (part# unknown, lot# unknown, quantity 3) this complaint involves one (1) device.This report is 1 of 1 for (b)(4).
 
Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.A review of the device history part: 03.010.103, lot: l427609, manufacturing site: bettlach, release to warehouse date: 20.June 2017.A manufacturing record evaluation was performed for the finished device lot number, and no non-conformances were identified.Investigation summary: according to the received pictures it cannot be confirmed that the drill bit was dull.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available (information or/and material), the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H10 additional narrative: d8; e1; h6.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
3.2MM THREE-FLUTED DRILL BIT QC/NEEDLE POINT/145MM
Type of Device
DRILL BIT
Manufacturer (Section D)
OBERDORF SYNTHES PRODUKTIONS GMBH
eimattstrasse 3
oberdorf 4436
SZ  4436
MDR Report Key8587112
MDR Text Key144710190
Report Number8030965-2019-63575
Device Sequence Number1
Product Code HTW
UDI-Device Identifier07611819775398
UDI-Public(01)07611819775398
Combination Product (y/n)N
PMA/PMN Number
EXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup,Followup
Report Date 04/09/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received05/07/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number03.010.103
Device Lot NumberL427609
Was Device Available for Evaluation? No
Date Manufacturer Received07/03/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
UNKNOWN SCREWS.
-
-