• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: DEPUY ORTHOPAEDICS INC US UNKNOWN HIP FEMORAL STEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DEPUY ORTHOPAEDICS INC US UNKNOWN HIP FEMORAL STEM Back to Search Results
Catalog Number UNK HIP FEMORAL STEM
Device Problem Inadequacy of Device Shape and/or Size (1583)
Patient Problems Pulmonary Embolism (1498); Unspecified Infection (1930); Thrombosis (2100)
Event Date 01/01/2017
Event Type  Injury  
Manufacturer Narrative
Product complaint # (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.(b)(4).
 
Event Description
An article was received entitled ¿highly cross-linked polyethylene reduces wear and revision rates in total hip arthroplasty¿.Literature article entitled, ¿highly cross-linked polyethylene reduces wear and revision rates in total hip arthroplasty a 10-year double-blinded randomized controlled trial¿ by peter a.Devane, mbchb, msc, fracs, et al, published by the journal of bone and joint surgery (2017), vol.99, pp.1703-1714 was reviewed for mdr reportability.The purpose of this study was to compare, in a double blinded randomized controlled trial with a minimum of 10 years of follow-up, the wear rates and clinical results of standard uhmwpe and xlpe using identical implant designs and fixation methods.We hypothesized that xlpe would be associated with less in vivo wear than conventional uhmwpe at 10 years following primary hip arthroplasty and that this would be associated with lower rates of osteolysis and improved prosthetic survival.An uncemented shell (duraloc sector; depuy) augmented with two 6.5-mm cancellous screws was used after under reaming by 1 mm to achieve initial press-fit.All patients received a charnley elite size-2 round back cemented femoral stem (depuy), a 28-mm cobalt-chromium femoral head (articul/eze; depuy), and a 28-mm inner-diameter polyethylene liner- either enduron or marathon.All patients were accounted for at the final follow-up.The authors observed no significant difference between the marathon (xlpe) and enduron (uhmwpe) groups with respect to age, sex, operative side, surgeon, cup size, or cup positioning (anteversion or abduction angle).Osteolysis was observed in 20 hips, and there was a significant difference in the prevalence between the 2 groups (16 [38%] of 42 in the enduron group and 4 [8%] of 49 in the marathon group.Postoperative complications included a nonfatal pulmonary embolus secondary to a deep venous thrombosis in 1 patient (marathon group) and a deep infection at 4 weeks treated with irrigation and debridement without exchange of the enduron liner in another.There were 6 dislocations, all occurring in patients in whom the posterior approach had been used.At the time of the latest follow-up, 21 patients had died (mean age at surgery, 67.2 years; range, 52 to 75 years); 12 of these patients had an enduron liner and 9, a marathon liner.All deaths, which occurred at a mean of 6.2 years (range, 0.7 to 10.3 years) postoperatively, were considered to be unrelated to the index surgery.There were 12 revisions, including 3 of the liner and femoral head because of excessive polyethylene wear, 6 due to femoral osteolysis or aseptic loosening of the stem, and 3 due to stem fracture (table iii).Ten of the revisions were performed in the enduron group and the other 2 (due to stem loosening caused by stem fracture in 1 and by cement mantle revisions were undertaken as a result of loosening of the acetabular shell.Patients with an enduron liner had a significantly higher revision rate than those with a marathon liner (fig.9; log-rank chi-square test (1 degree of freedom [df]) = 6.3; p = 0.012), with the first revisions seen after just 5 years.The patients treated with the enduron liner had a significantly higher prevalence of osteolysis.The 3 stem fractures were a fault of the study design, ith the use of a charnley elite size 2 for all patients leading to undersizing in some patients and causing the stem to fracture.There were 6 hips with dislocations.All were treated with closed reduction, one was revised 8 years after index tha for osteolysis.This complaint will have a total of 17 pcs.The parent pc will include perioperative complications associated with the implants.Case 1-case 18 will capture the specific adverse events associate with specific patients noted in table ii and table vii within the study.Please link all 18 additional pc-s to the parent (b)(4).
 
Manufacturer Narrative
Product complaint # (b)(4).Investigation summary
=
> no device was received.Root cause undetermined.Depuy synthes considers the investigation closed at this time.Should additional information be received, the information will be reviewed and the investigation may be re-opened as necessary.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN HIP FEMORAL STEM
Type of Device
HIP FEMORAL STEM
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
Manufacturer (Section G)
JTE WARSAW MFG SITE
700 orthopaedic drive
warsaw IN 46582
Manufacturer Contact
kara ditty-bovard
700 orthopaedic drive
warsaw, IN 46581-0988
6107428552
MDR Report Key9109890
MDR Text Key164610034
Report Number1818910-2019-105859
Device Sequence Number1
Product Code KXA
Combination Product (y/n)N
Reporter Country CodeNZ
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,literature
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 09/05/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/24/2019
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberUNK HIP FEMORAL STEM
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received11/18/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-