MAUDE Adverse Event Report: ROCHE DIAGNOSTICS ELECSYS PROLACTIN ASSAY; RADIOIMMUNOASSAY, PROLACTIN (LACTOGEN)

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ROCHE DIAGNOSTICS ELECSYS PROLACTIN ASSAY; RADIOIMMUNOASSAY, PROLACTIN (LACTOGEN) Back to Search Results
Model Number PROLACTIN G2
Device Problem Low Test Results (2458)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 08/30/2019
Event Type  malfunction  
Manufacturer Narrative
This event occurred in (b)(6).
 
Event Description
The initial reporter complained of questionable thyroid results for 1 patient sample on a cobas 8000 e 801 module compared to competitor methods.The initial results from the customer's e 801 were reported outside of the laboratory.The competitor methods were considered correct.There were discrepant results for elecsys ft3 iii, elecsys prolactin assay, elecsys estradiol assay, elecsys testosterone ii assay from the customer's e 801 module compared the siemens centaur method.There were discrepant results for elecsys tsh assay from the customer's e 801 module compared to the siemens centaur and beckman methods.There were discrepant results for roche diagnostics cobas elecsys anti-tpo from the customer's e 801 module compared to the beckman method.There were discrepant results for elecsys dhea-s from the customer's e 801 module compared to the siemens immulite 2000 method.This medwatch will cover prolactin.Refer to medwatch with patient identifier (b)(6) for information on the tsh results, medwatch with patient identifier (b)(6) for information on the ft3 iii results, medwatch with patient identifier (b)(6) for information on the estradiol results, medwatch with patient identifier (b)(6) for information on the testosterone results, medwatch with patient identifier (b)(6) for information on the anti-tpo results, and medwatch with patient identifier (b)(6) for information on the dhea-s results.The customer's cobas e 602 module serial number was not provided.
 
Manufacturer Narrative
One patient sample was returned for investigation.The investigation identified an interfering factor against the streptavidin component of the reagent in the sample.The interfering factor is documented in product labeling which states: interference in the method sheets of all applicable products: in rare cases, interference due to extremely high titers of antibodies to analyte-specific antibodies, streptavidin or ruthenium can occur.These effects are minimized by suitable test design.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ELECSYS PROLACTIN ASSAY
Type of Device
RADIOIMMUNOASSAY, PROLACTIN (LACTOGEN)
Manufacturer (Section D)
ROCHE DIAGNOSTICS
9115 hague road
indianapolis IN 46250 0457
MDR Report Key9151864
MDR Text Key219582770
Report Number1823260-2019-03548
Device Sequence Number1
Product Code CFT
Combination Product (y/n)N
PMA/PMN Number
K964748
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,u
Type of Report Initial,Followup
Report Date 12/30/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/03/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date10/31/2019
Device Model NumberPROLACTIN G2
Device Catalogue Number03203093190
Device Lot Number37994400
Was Device Available for Evaluation? Yes
Date Manufacturer Received09/09/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
L-THYROXIN
-
-