Catalog Number UNKNOWN |
Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problem
Perforation of Esophagus (2399)
|
Event Date 08/23/2011 |
Event Type
Injury
|
Manufacturer Narrative
|
Usage of device is unknown.Familiari, p., costamagna, g., bléro, d., moine, o.L., perri, v., boskoski, i., devière, j.(2011).Transoral gastroplasty for morbid obesity: a multicenter trial with a 1-year outcome.Gastrointestinal endoscopy, 74(6), 1248¿1258.Doi: 10.1016/j.Gie.2011.08.046.Concomitant medical products: toga sleeve stapler, olympus gif p140 or gif xp160 or gif xp180.This investigation is on-going.Once complete, a follow-up emdr report will be provided.
|
|
Event Description
|
Cook endoscopy was notified of an events that occurred with the savary-gilliard wire guide.Please see below for relevant excerpts of this article."in an operating room (rome) or anesthesia-equipped endoscopy suite (brussels), patients were positioned supine with shoulders raised by using a positioning pillow.Patients were administered general anesthesia preferably via nasotracheal intubation.Oral tracheal intubation was performed alternatively.Upper gi endoscopy was performed, and a metallic stiff guidewire (savary-gilliard wire guide; cook medical, winston-salem, nc) was passed into the stomach.A 54f then 60f bougie (savary-gilliard dilators; cook medical) was passed to dilate the esophagus and test for resistance.The toga sleeve stapler was passed into the stomach over the guidewire, and a small caliber endoscope (olympus gif p140 or gif xp160 or gif xp180; olympus co, ltd, tokyo, japan) was passed through the device into the stomach for visualization during the procedure (fig.2a).A patient experienced an asymptomatic pneumoperitoneum [indication of perforation] identified on a radiograph before discharge [subject of report].The patient was administered antibiotics and monitored until the condition resolved.No fever or signs of peritonitis were seen." it was not published in the article if a section of the device remained inside the patient¿s body.The patient was administered antibiotics and monitored until the condition resolved.There was no fever or signs of peritonitis.
|
|
Manufacturer Narrative
|
H8: usage of device is unknown familiari, p., costamagna, g., bléro, d., moine, o.L., perri, v., boskoski, i., ¿ devière, j.(2011).Transoral gastroplasty for morbid obesity: a multicenter trial with a 1-year outcome.Gastrointestinal endoscopy, 74(6), 1248¿1258.Doi: 10.1016/j.Gie.2011.08.046 continued from section d11:toga sleeve stapler, olympus gif p140 or gif xp160 or gif xp180 investigation evaluation: a product evaluation was not performed in response to this report because the product said to be involved was not provided to cook for evaluation.The report could not be confirmed.A review of the device history record could not be conducted because the lot number was not provided.Investigation conclusion: we could not conduct a complete investigation because the product said to be involved was not returned for evaluation.A definitive cause for the reported observation could not be determined.Prior to distribution, all savary-gilliard wire guides are subjected to a visual inspection to ensure device integrity.Corrective action: a review of the complaint history was conducted.The likelihood of occurrence is considered rare.Corrective action is not warranted at this time based on the quality engineering risk assessment.Quality assurance will continue to monitor for complaint trends and reassess the risk assessment results as post market feedback continues to become available.
|
|
Event Description
|
Cook endoscopy was notified of an events that occurred with the savary-gilliard wire guide.Please see below for relevant excerpts of this article."in an operating room (rome) or anesthesia-equipped endoscopy suite (brussels), patients were positioned supine with shoulders raised by using a positioning pillow.Patients were administered general anesthesia preferably via nasotracheal intubation.Oral tracheal intubation was performed alternatively.Upper gi endoscopy was performed, and a metallic stiff guidewire (savary-gilliard wire guide; cook medical, winston-salem, nc) was passed into the stomach.A 54f then 60f bougie (savary-gilliard dilators; cook medical) was passed to dilate the esophagus and test for resistance.The toga sleeve stapler was passed into the stomach over the guidewire, and a small caliber endoscope (olympus gif p140 or gif xp160 or gif xp180; olympus co, ltd, tokyo, japan) was passed through the device into the stomach for visualization during the procedure (fig.2a).A patient experienced an asymptomatic pneumoperitoneum [indication of perforation] identified on a radiograph before discharge [subject of report].The patient was administered antibiotics and monitored until the condition resolved.No fever or signs of peritonitis were seen." it was not published in the article if a section of the device remained inside the patient¿s body.The patient was administered antibiotics and monitored until the condition resolved.There was no fever or signs of peritonitis.
|
|