• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: TERUMO CARDIOVASCULAR SYSTEMS CORPORATION STERILE FX25REC W/RES; BLOOD GAS OXYGENATOR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TERUMO CARDIOVASCULAR SYSTEMS CORPORATION STERILE FX25REC W/RES; BLOOD GAS OXYGENATOR Back to Search Results
Model Number 3CX*FX25REC
Device Problem Component Missing (2306)
Patient Problem No Patient Involvement (2645)
Event Date 11/08/2019
Event Type  malfunction  
Manufacturer Narrative
Terumo has received the device for evaluation; however, the investigation has yet to be completed.Terumo plans on submitting a follow-up report when the investigation is complete and when more information becomes available.(b)(4).
 
Event Description
The user facility reported to terumo cardiovascular that prior to cardiopulmonary bypass, during out of box, the arterial temperature connection was missing.No patient involvement.
 
Manufacturer Narrative
This follow-up report is submitted to fda in accord with applicable regulations ¿ and as indicated by terumo cardiovascular systems in the initial report submitted to the fda on (b)(6) 2019.Upon further investigation of the reported event, the following information is new and/or changed: (additional device information - added expiration date).(date received by manufacturer).(indication that this is a follow-up report).(follow-up due to additional information and device evaluation).(device evaluated by manufacturer).(device manufacture date).(identification of evaluation codes 10,11, 3331, 3259, 25).Method code #1: 10 - testing of actual/suspected device.Method code #2: 11 - testing of device from same lot/batch retained by manufacturer.Method code #3: 3331 - analysis of production records.Results code: 3259 - improper physical structure.Conclusions code: 25 - cause traced to manufacturing.The affected sample was reviewed upon receipt confirming the missing arterial thermistor.The most likely cause is the thermistor had no or an insufficient amount of bonding agent applied.This would allow the thermistor to be inserted into the port and remain in the port for a period of time, but not be securely affixed in the port to where it would fall out after packaging.A training was conducted with the production associates to make them aware of this event and to ensure that all thermistors, and other components, are properly assembled and inspected on the reservoir and oxygenator.All available information has been placed on file in quality management for appropriate tracking, trending, and follow-up.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STERILE FX25REC W/RES
Type of Device
BLOOD GAS OXYGENATOR
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORPORATION
125 blue ball road
elkton MD 21921
MDR Report Key9379351
MDR Text Key168839615
Report Number1124841-2019-00320
Device Sequence Number1
Product Code DTZ
UDI-Device Identifier00699753450820
UDI-Public(01)00699753450820
Combination Product (y/n)N
PMA/PMN Number
K151791
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 12/27/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/26/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date07/31/2022
Device Model Number3CX*FX25REC
Device Catalogue NumberN/A
Device Lot NumberXK05
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/13/2019
Was the Report Sent to FDA? No
Date Manufacturer Received12/20/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-