Catalog Number UNK HIP FEMORAL HEAD
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Death (1802); Myocardial Infarction (1969); Respiratory Failure (2484)
Event Date 08/21/2008
Event Type  Death  
Manufacturer Narrative
Product complaint # (b)(4).Investigation summary: no device associated with this report was received for examination.A worldwide lot specific complaint database search, or device history record (dhr) review was not possible because the required lot code(s) was not provided.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Corrective action was not indicated.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Report source is a literature article.There is limited information regarding the reported death.
 
Event Description
"literature article entitled, ¿cemented versus uncemented hemiarthroplasty for displaced femoral neck fractures¿ by wender figved md, et al, published by clinical orthopaedic related research (2009), vol.467, pp.2426-2435, was reviewed.The purpose of this article is to compare the results of cemented versus uncemented hemiarthroplasties implanted into the frail elderly after a displaced femoral neck fracture.This complaint will capture the initial study results as well as the results of the 5 year follow up.Implanted depuy products: all patient received a depuy bipolar head (mobile bipolar head and cocr modular head).The cemented group was implanted with a competitor stem secured with competitor cement.The cementless group was implanted with a corail femoral stem.Results: the authors provide a detailed list of patients and postoperative outcomes.These cases are detailed within the guidance document labeled case 1-case 16.This parent complaint will capture the deaths noted in the study and the additional results provided within the 5 year follow up.There were 4 deaths that occurred within 72 hours of the index operation.One patient experienced a severe decrease in blood pressure during the cementing procedure and died within 24 hours owing to an acute myocardial infarction.This death is attributed to the competitor cement and will not be included in this complaint.Another patient in the cemented group experienced cardiac arrest during wound closure and died of a myocardial infarction within 72 hours.The only depuy product used in this procedure was the depuy bipolar head- the stem and the cement were competitor products.2 patients died of respiratory failure within 72 hours of index surgery.In the five-year follow-up, the authors note there were 3 additional periprosthetic femoral fractures treated with internal fixation.Captured in (b)(4): mobile bipolar head, cocr modular head, and corail stem: death.Corail stem: no reported product problem.Patient harms: myocardial infarction, cardiac arrest, respiratory failure, fracture post op, surgical intervention.The corail stem will not be coded for cardiac arrest and myocardial infarction because this implant was not used in the cemented procedure.Case 1 through case 16 are linked to (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN HIP FEMORAL HEAD
Type of Device
HIP FEMORAL HEAD
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
Manufacturer (Section G)
JTE WARSAW MFG SITE
700 orthopaedic drive
warsaw IN 46582
Manufacturer Contact
kara ditty-bovard
700 orthopaedic drive
warsaw, IN 46581-0988
6107428552
MDR Report Key9382587
MDR Text Key168195425
Report Number1818910-2019-118231
Device Sequence Number1
Product Code KXA
Combination Product (y/n)N
Reporter Country CodeNO
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,literature
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 11/06/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/27/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue NumberUNK HIP FEMORAL HEAD
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received11/06/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Death;
-
-