Model Number 53401
Device Problem Device Difficult to Program or Calibrate (1496)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 11/21/2019
Event Type  Injury  
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event Description
It was reported when using the external pulse generator (epg) it will initially pace normally but appears to experience a reset and it goes back to default settings and not what the device was previously set to and pacing at.The external pulse generator (epg) was reported to be working on an old firmware version.It was advised that the unit should be removed from service and sent in for servicing in order to get the correct firmware update installed.A patient was connected with the device at the time the event occurred.No patient complications have been reported as a result of this event.
 
Manufacturer Narrative
The external pulse generator (epg) passed all incoming inspection.Power on reset (por) firmware was updated.The epg passed all final functional tests.If information is provided in the future, a supplemental report will be issued.
 
Event Description
The external pulse generator (epg) was returned for service.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TEMPORARY EXTERNAL PACEMAKER
Type of Device
PULSE-GENERATOR, PACEMAKER, EXTERNAL
Manufacturer (Section D)
PLEXUS MANUFACTURING SDN. BHD
bayan lepas free industrial zo
bayan lepas 11900
MY  11900
Manufacturer (Section G)
PLEXUS MANUFACTURING SDN. BHD
bayan lepas free industrial zo
bayan lepas 11900
MY   11900
Manufacturer Contact
paula bixby
8200 coral sea st ne
mounds view, MN 55112
7635055378
MDR Report Key9503415
MDR Text Key172218453
Report Number3004593495-2019-01339
Device Sequence Number1
Product Code DTE
UDI-Device Identifier00643169723160
UDI-Public00643169723160
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K162054
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional,user faci
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 03/26/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/20/2019
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number53401
Device Catalogue Number53401
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/03/2020
Is the Reporter a Health Professional? Yes
Date Manufacturer Received03/10/2020
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured03/02/2017
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-