• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BIOSENSE WEBSTER INC EZ STEER¿ NAV BI-DIRECTIONAL ELECTROPHYSIOLOGY CATHETER; ELECTRODE, PERCUTANEOUS, CONDUCTION TISSUE ABLATION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BIOSENSE WEBSTER INC EZ STEER¿ NAV BI-DIRECTIONAL ELECTROPHYSIOLOGY CATHETER; ELECTRODE, PERCUTANEOUS, CONDUCTION TISSUE ABLATION Back to Search Results
Catalog Number BN7TCDF4L
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Arrhythmia (1721); No Code Available (3191)
Event Date 12/09/2019
Event Type  Injury  
Manufacturer Narrative
Patient code of ¿no code available¿ represents ¿surgical intervention¿.The device has been reported as discarded, therefore no product investigation can be performed, and the customer complaint cannot be confirmed.If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.Manufacturing record evaluation (mre) review cannot be conducted because no lot number was provided by the customer.Manufacturer's reference # (b)(4).
 
Event Description
It was reported that a patient underwent an atrioventricular nodal reentrant tachycardia (avnrt) ablation procedure with an ez steer¿ nav bi-directional electrophysiology catheter and suffered a heart block requiring a temporary pacemaker.During the procedure, a second-degree heart block was discovered and confirmed with an electrocardiogram.The electrogram showed atrial without ventricular conduction.A temporary pacemaker was inserted.The patient was reported to be in stable condition but had a prolonged pr interval.Additional hospitalization was required for monitoring the heart block condition.The patient¿s condition has improved.The physician¿s opinion on the cause of the adverse event was procedure related.The ablation was set at 30 watts and the temperature was 55°c.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EZ STEER¿ NAV BI-DIRECTIONAL ELECTROPHYSIOLOGY CATHETER
Type of Device
ELECTRODE, PERCUTANEOUS, CONDUCTION TISSUE ABLATION
Manufacturer (Section D)
BIOSENSE WEBSTER INC
33 technology drive
irvine CA 92618
Manufacturer (Section G)
BIOSENSE WEBSTER INC (JUAREZ)
circuito interior norte
1820parque industrial salvacar
juarez 32599
MX   32599
Manufacturer Contact
gabriel alfageme
31 technology drive
irvine, CA 92618
949789-868
MDR Report Key9536392
MDR Text Key188861246
Report Number2029046-2019-04086
Device Sequence Number1
Product Code LPB
UDI-Device Identifier10846835002997
UDI-Public10846835002997
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P990025/S12
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Physician
Type of Report Initial
Report Date 12/09/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/31/2019
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue NumberBN7TCDF4L
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received12/09/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Required Intervention;
-
-