Catalog Number 8065977763
Device Problems Break (1069); Crack (1135)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 11/04/2019
Event Type  malfunction  
Manufacturer Narrative
The used artridge was returned.Inadequate viscoelastic is observed in the cartridge.There is evidence the cartridge was placed into a handpiece.The cartridge nozzle has an aneurysm that changes to a split as it enters the thinner tip material.Heavy stress is also observed.Only half of the lens was found in the returned bag.The haptic was intact on the returned portion.The lens was cut through the center typical of removal.Product history records were reviewed and documentation indicated the product met release criteria.Indicated associated products are qualified for use with the cartridge.The root cause for the reported lens damage may be related to a failure to follow the dfu.There did not appear to be adequate viscoelastic in the cartridge.The dfu instructs to fill the cartridge with viscoelastic before loading the lens.The returned cartridge nozzle has an aneurysm that splits as it extends into the thinner tip area.This type of damage is typically progressive and worsens as the lens is advanced.The damage on the top of the nozzle started in the thick wall cone area.Unusually high internal forces would be needed to create damage in this area.The two distinct areas of damage would indicate a progressive change that occurred as the lens was advanced.This type of damage typically occurs if the lens is not positioned correctly for advancement; if there is a lack of viscoelastic between the lens and the cartridge lumen; if the lens is advanced too rapidly or if the handpiece plunger is not positioned correctly at the trailing optic edge.If the handpiece plunger is not positioned at the trailing optic edge it can allow the lens to fold around the plunger tip making it too large to correctly advance through the narrow tip of the cartridge, which could cause damage to the tip or the lens.There are no other complaints in the reported lot.The manufacturer internal reference number is: (b)(4).
 
Event Description
A facility representative reported that during an intraocular lens (iol) implant procedure, the cartridge cracked and broke the lens haptic as the lens was being pushed through the cartridge tip.The lens was removed and another lens was implanted instead.There was no reported patient impact.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MONARCH III IOL DELIVERY SYSTEM, CARTRIDGE D
Type of Device
FOLDERS AND INJECTORS, INTRAOCULAR LENS (IOL)
Manufacturer (Section D)
ALCON RESEARCH, LLC - HUNTINGTON
6065 kyle lane
huntington WV 25702
Manufacturer (Section G)
ALCON RESEARCH, LLC - HUNTINGTON
6065 kyle lane
huntington WV 25702
Manufacturer Contact
jason michaelides
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8175686438
MDR Report Key9667441
MDR Text Key181931674
Report Number1119421-2020-00185
Device Sequence Number1
Product Code MSS
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K063155
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type other
Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date 02/04/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/04/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number8065977763
Device Lot Number32726056
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/14/2020
Date Manufacturer Received11/25/2019
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured08/13/2019
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-