STRYKER GMBH UNKNOWN CHROME-COBALT NECK-HEAD; IMPLANT Back to Search Results
Catalog Number UNK_SEL
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Pain (1994); Injury (2348)
Event Date 06/01/2013
Event Type  Injury  
Manufacturer Narrative
This complaint has been reported during a literature review performed by the post market surveillance group.The reported event could not be confirmed, since the device was not returned for evaluation and no other additional information is available.More detailed information about the complaint event as well as the affected device must be available in order to determine the root cause of the complaint event.The device history record could not be reviewed because the affected lot number was not communicated.If any further information is provided, the investigation report will be updated.Device disposition is unknown.
 
Event Description
The manufacturer became aware of a pmcf from (b)(6).The title of this report is ¿2 year follow up of the moovis press fit trapeziometacarpal joint arthroplasty¿ which is associated with the stryker ¿moovis¿ system.Within that publication, post-operative complications/ adverse events were reported, which occurred from june 2013 to march 2015.It was not possible to ascertain specific device details from the report, a review of the complaint handling database, however, revealed that the events have not been reported by the hospital or by the author of the publication, therefore 24 complaints were initiated retrospectively for adverse events mentioned in the report.This product inquiry addresses painful impingement followed by revision.2 out of 2 cases.The report states: ¿within 12 and 24 months two patients had painful impingement and were re-operated with insertion of a longer neck segment.¿.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN CHROME-COBALT NECK-HEAD
Type of Device
IMPLANT
Manufacturer (Section D)
STRYKER GMBH
bohnackerweg 1
postfach
selzach 2545
CH  2545
Manufacturer (Section G)
STRYKER GMBH
bohnackerweg 1
postfach
selzach 2545
CH   2545
Manufacturer Contact
anna jusinski
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key9673207
MDR Text Key189057573
Report Number0008031020-2020-00309
Device Sequence Number1
Product Code MPK
Combination Product (y/n)N
Reporter Country CodeDK
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Reporter Occupation Physician
Type of Report Initial
Report Date 02/05/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/05/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Lay User/Patient
Device Catalogue NumberUNK_SEL
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received01/08/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-