Date of Entry
|
Specialty Task Group Area
|
Recognition Number
|
Extent of Recognition
|
Standards Developing Organization
|
Standard Designation Number and Date
|
Standard Title (click for recognition information)
|
07/06/2020 |
Cardiovascular |
3-123 |
Partial |
IEC |
80601-2-30: Edition 2.0 2018-03 |
Medical electrical equipment - Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers |
ANSI AAMI IEC |
80601-2-30:2018 |
Medical electrical equipment - Part 2-30: Particular requirements for basic safety and essential performance of automated type non-invasive sphygmomanometers |
12/18/2023 |
Cardiovascular |
3-105 |
Partial |
IEC |
60601-2-25 Edition 2.0 2011-10 |
Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs |
ANSI AAMI IEC |
60601-2-25:2011/(R)2016 |
Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs |
12/18/2023 |
Cardiovascular |
3-126 |
Partial |
IEC |
60601-2-27 Edition 3.0 2011-03 |
Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment [Including: Corrigendum 1 (2012)] |
ANSI AAMI IEC |
60601-2-27:2011(R)2016 |
Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment |
06/27/2016 |
Radiology |
12-302 |
Partial |
IEC |
60601-2-44 Edition 3.2: 2016 |
Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of x-ray equipment for computed tomography |
09/17/2018 |
General II (ES/ EMC) |
19-19 |
Partial |
IEC |
TR 60601-4-2 Edition 1.0 2016-05 |
Medical electrical equipment - Part 4-2: Guidance and interpretation - Electromagnetic immunity: performance of medical electrical equipment and medical electrical systems |
06/27/2016 |
Radiology |
12-295 |
Partial |
IEC |
60601-2-33 Ed. 3.2 b:2015 |
Medical electrical equipment - Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis |
12/18/2023 |
Radiology |
12-348 |
Partial |
IEC |
60601-2-54 Edition 2.0 2022-09 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy |
12/20/2021 |
General II (ES/ EMC) |
19-43 |
Partial |
IEC |
61326-2-6 Edition 3.0 2020-10 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment |
12/20/2021 |
General II (ES/ EMC) |
19-42 |
Partial |
IEC |
61326-1 Edition 3.0 2020-10 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
06/07/2021 |
General Plastic Surgery/ General Hospital |
6-389 |
Partial |
IEC |
60601-2-2 Edition 6.0 2017-03 |
Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories |
ANSI AAMI IEC |
60601-2-2:2017 |
Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories |
12/21/2020 |
Cardiovascular |
3-169 |
Partial |
IEC |
60601-2-4 Edition 3.1 2018-02 CONSOLIDATED VERSION |
Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators |
ANSI AAMI IEC |
60601-2-4:2010/A1:2018 (Consolidated Text) |
Medical electrical equipment Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators, including Amendment 1 |
12/21/2020 |
General II (ES/ EMC) |
19-38 |
Partial |
IEC |
60601-1-11 Edition 2.1 2020-07 CONSOLIDATED VERSION |
Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment |
12/21/2020 |
General II (ES/ EMC) |
19-36 |
Partial |
IEC |
60601-1-2 Edition 4.1 2020-09 CONSOLIDATED VERSION |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
ANSI AAMI IEC |
60601-1-2:2014 [Including AMD 1:2021] |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests [Including Amendment 1 (2021)] |
12/23/2016 |
Radiology |
12-303 |
Complete |
IEC |
61303 Edition 1.0 1994-09 |
Medical electrical equipment - Radionuclide calibrators - Particular methods for describing performance [Including CORRIGENDUM 1 (2016)] |
12/23/2016 |
Radiology |
12-304 |
Complete |
IEC |
60731 Edition 3.1 2016-04 |
Consolidated Version Medical electrical equipment - Dosimeters with ionization chambers as used in radiotherapy |
03/16/2012 |
Radiology |
12-241 |
Complete |
IEC |
62274 First Edition 2005-05 |
Medical electrical equipment - Safety of radiotherapy record and verify systems |
08/06/2013 |
Radiology |
12-253 |
Complete |
IEC |
60976 Edition 2.0 2007-10 |
Medical electrical equipment - Medical electron accelerators - Functional performance characteristics |
08/06/2013 |
Radiology |
12-255 |
Complete |
IEC |
60601-2-11 Edition 3.0 2013-01 |
Medical electrical equipment - Part 2-11: Particular requirements for the basic safety and essential performance of gamma beam therapy equipment |
07/09/2014 |
Radiology |
12-275 |
Complete |
IEC |
61161 Edition 3.0 2013-01 |
Ultrasonics -- Power measurement -- Radiation force balances and performance requirements |
07/09/2014 |
Radiology |
12-280 |
Complete |
IEC |
62555 Edition 1.0 2013-11 |
Ultrasonics -- Power measurement -- High intensity therapeutic ultrasound (HITU) transducers and systems |
07/09/2014 |
Radiology |
12-281 |
Complete |
IEC |
60601-2-62 Edition 1.0 2013-07 |
Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment |
10/04/2010 |
Radiology |
12-213 |
Complete |
IEC |
62220-1-2 Edition 1.0 2007-06 |
Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-2: Determination of the detective quantum efficiency - Detectors used in mammography |
10/04/2010 |
Radiology |
12-214 |
Complete |
IEC |
62220-1-3 Edition 1.0 2008-06 |
Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-3: Determination of the detective quantum efficiency - Detectors used in dynamic imaging |
08/14/2015 |
Radiology |
12-290 |
Complete |
IEC |
61910-1 Edition 1.0 2014-09 |
Medical electrical equipment - Radiation dose documentation - Part 1: Radiation dose structured reports for radiography and radioscopy |
06/07/2021 |
General Plastic Surgery/ General Hospital |
6-463 |
Complete |
IEC |
60601-2-21 Edition 3.0 2020-09 |
Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers |