Date of Entry
|
Specialty Task Group Area
|
Recognition Number
|
Extent of Recognition
|
Standards Developing Organization
|
Standard Designation Number and Date
|
Standard Title (click for recognition information)
|
03/16/2012 |
Radiology |
12-242 |
Complete |
IEC |
60601-2-57 Edition 1.0 2011-01 |
Medical Electrical Equipment - Part 2-57: Particular requirements for the basic safety and essential performance of non-laser light source equipment intended for therapeutic, diagnostic, monitoring and cosmetic/aesthetic use |
08/20/2012 |
Radiology |
12-249 |
Complete |
IEC |
62471 First edition 2006-07 |
Photobiological safety of lamps and lamp systems |
08/06/2013 |
Radiology |
12-253 |
Complete |
IEC |
60976 Edition 2.0 2007-10 |
Medical electrical equipment - Medical electron accelerators - Functional performance characteristics |
08/06/2013 |
Radiology |
12-255 |
Complete |
IEC |
60601-2-11 Edition 3.0 2013-01 |
Medical electrical equipment - Part 2-11: Particular requirements for the basic safety and essential performance of gamma beam therapy equipment |
01/30/2014 |
Radiology |
12-259 |
Complete |
IEC |
61674 Edition 2.0 2012-11 |
Medical electrical equipment -- Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging |
01/30/2014 |
Radiology |
12-261 |
Complete |
ISO IEC |
10918-1 First edition 1994-02-15 |
Information technology - Digital compression and coding of continuous-tone still images: Requirements and guidelines [Including: Technical Corrigendum 1 (2005)] |
01/30/2014 |
Radiology |
12-266 |
Complete |
IEC |
61689 Edition 3.0 2013-02 |
Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0.5 MHz to 5 MHz |
01/30/2014 |
Radiology |
12-267 |
Complete |
IEC |
61217 Edition 2.0 2011-12 |
Radiotherapy equipment - Coordinates, movements, and scales |
01/14/2014 |
Radiology |
12-268 |
Complete |
IEC |
60601-2-22 Edition 3.1 2012-10 |
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment |
07/09/2014 |
Radiology |
12-272 |
Complete |
IEC |
60601-2-17 Edition 3.0 2013-11 |
Medical electrical equipment - Part 2-17: Particular requirements for the safety of automatically-controlled brachytherapy afterloading equipment |
07/09/2014 |
Radiology |
12-273 |
Complete |
IEC |
60825-1 Edition 2.0 2007-03 |
Safety of laser products - Part 1: Equipment classification, and requirements [Including: Technical Corrigendum 1 (2008), Interpretation Sheet 1 (2007), Interpretation Sheet 2 (2007)] |
07/09/2014 |
Radiology |
12-275 |
Complete |
IEC |
61161 Edition 3.0 2013-01 |
Ultrasonics -- Power measurement -- Radiation force balances and performance requirements |
07/09/2014 |
Radiology |
12-279 |
Complete |
IEC |
62127-03 Edition 1.1 2013-05 |
Ultrasonics -- Hydrophones -- Part 3: Properties of hydrophones for ultrasonic fields up to 40 MHz |
07/09/2014 |
Radiology |
12-280 |
Complete |
IEC |
62555 Edition 1.0 2013-11 |
Ultrasonics -- Power measurement -- High intensity therapeutic ultrasound (HITU) transducers and systems |
07/09/2014 |
Radiology |
12-281 |
Complete |
IEC |
60601-2-62 Edition 1.0 2013-07 |
Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment |
08/14/2015 |
Radiology |
12-289 |
Complete |
IEC |
62220-1-1 Edition 1.0 2015-03 |
Medical electrical equipment-Characteristics of digital X-ray imaging devices Part 1-1: Determination of the detective quantum efficiencyDetectors used in radiographic imaging |
08/14/2015 |
Radiology |
12-290 |
Complete |
IEC |
61910-1 Edition 1.0 2014-09 |
Medical electrical equipment - Radiation dose documentation - Part 1: Radiation dose structured reports for radiography and radioscopy |
08/14/2015 |
Radiology |
12-291 |
Complete |
IEC |
62127-2 Edition 1.2 2017-03 CONSOLIDATED VERSION |
Ultrasonics -- Hydrophones -- Part 2: Calibration for ultrasonic fields up to 40 MHz |
06/27/2016 |
Radiology |
12-293 |
Complete |
IEC |
60601-2-37 Edition 2.1 2015 |
Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment |
06/27/2016 |
Radiology |
12-294 |
Complete |
IEC |
60601-2-45 Edition 3.1 2015 |
Medical electrical equipment - Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices |
06/27/2016 |
Radiology |
12-295 |
Partial |
IEC |
60601-2-33 Ed. 3.2 b:2015 |
Medical electrical equipment - Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis |
06/27/2016 |
Radiology |
12-301 |
Complete |
IEC |
60601-2-8 Edition 2.1 b:2015 |
Medical electrical equipment - Part 2-8: Particular requirements for the safety of therapeutic X-ray equipment operating in the range 10 kV to 1 MV |
06/27/2016 |
Radiology |
12-302 |
Partial |
IEC |
60601-2-44 Edition 3.2: 2016 |
Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of x-ray equipment for computed tomography |
12/23/2016 |
Radiology |
12-303 |
Complete |
IEC |
61303 Edition 1.0 1994-09 |
Medical electrical equipment - Radionuclide calibrators - Particular methods for describing performance [Including CORRIGENDUM 1 (2016)] |
12/23/2016 |
Radiology |
12-304 |
Complete |
IEC |
60731 Edition 3.1 2016-04 |
Consolidated Version Medical electrical equipment - Dosimeters with ionization chambers as used in radiotherapy |