| | Class 2 Device Recall S TBone Plate; M TCompression Plate; |  |
| Date Initiated by Firm | May 26, 2006 |
| Date Posted | February 16, 2011 |
| Recall Status1 |
Terminated 3 on December 08, 2014 |
| Recall Number | Z-1334-2011 |
| Recall Event ID |
50094 |
| 510(K)Number | K062498 |
| Product Classification |
Plate, fixation bone - Product Code HRS
|
| Product | S T-Bone Plate;
M T-Compression Plate;
Manufactured and Distributed by Stryker Lebinger GmbH & Co.
Freiburg, Germany.
The Profyle System is intended for use in internal fixation of the bones of hand and wrist. Examples of these procedures may include but are not limited to replantation, lag screws techniques, joint fusion, corrective osteotomies, and the treatment of fractures |
| Code Information |
S T-Bone Plate, Product number: 57-05260; Lot Code G4M 00F1576; M T-Compression Plate, Product number 57-10260; Lot Code G4N00F1584 |
| FEI Number |
3003070421
|
Recalling Firm/ Manufacturer |
Stryker Howmedica Osteonics Corp.
325 Corporate Dr
Mahwah
NJ
07430
|
| For Additional Information Contact | Rita Intorella 201-831-5825 |
Manufacturer Reason for Recall | A package labeled as a S T-Bone Plate, Catalog Number 57-05260, Lot Code G4M00F1576, may actually contain a M T-Compression Plate, Catalog Number 57-10250, Lot Code G4N00F1584 and vice versa. |
FDA Determined Cause 2 | Process design |
| Action | Stryker Orthopedics sent an Important Market Withdrawal letter dated May 26, 2006, by Federal Express to all affected customers. The letter identified the product, the problem, and the action to be taken by the customer.
Customers were instructed to examine their inventory, including their hospital consignment location, to identify the product.
If the affected product remained in its original packaging, customers were instructed to retrieve all of the affected product lots and return it to their branch or agency warehouse for reconcillation.
Reconcile all product on the attached Product Accountability Form and fax a copy of the form to 201-831-6069 within 5 days of receipt of the notice.
Customers were asked to return the affected product via Inter-Org Transfer and ship to Product Surveillance, Stryker Orthopaedics, 325 Corporate Drive, Mahwah, New Jersey, USA 07430-2104.
Customers were also instructed to contact their Stryker Orthopaedics Customer Service representataive to re-order the product that they were returning.
For questions regarding this recall call (201) 831-5825. |
| Quantity in Commerce | 21 |
| Distribution | Nationwide Distribution |
| Total Product Life Cycle | TPLC Device Report |
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls. 2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall. 3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 �7.55.
|
| 510(K) Database | 510(K)s with Product Code = HRS
|
|
|
|