| | Class 2 Device Recall Zimmer Periarticular Locking Plate System Distal Lateral Fibula Locking Plate |  |
| Date Initiated by Firm | March 20, 2024 |
| Date Posted | April 30, 2024 |
| Recall Status1 |
Open3, Classified |
| Recall Number | Z-1728-2024 |
| Recall Event ID |
94276 |
| 510(K)Number | K070906 |
| Product Classification |
Screw, fixation, bone - Product Code HWC
|
| Product | ZPLP Distal Lateral Fibular Plate, Left, 8 Holes, 132 MM, Nonsterile-Indicated for temporary internal fixation and stabilization of osteotomies and fractures
Item Number: 00-2357-018-08 |
| Code Information |
GTIN: 00889024055926
Lot Numbers:
Lot Number
64370324
64370328
64370332
64370333
64370337
64370339
64370341
64370344
64370353
64370354
64370364
64370365
64370366
64370368
64370369
64370370
64406604
64406606
64406609
64406611
64406618
64406619
64406620
64406622
64406625
64406626
64452251
64452252
64452253
64464635
64464647
64464648
64464649
64464651
64464652
64464654
64464656
64464658
64464659
64464660
64464661
64464662
64464664
64464666
64464667
64475555
64475556
64488018
64488021
64488023
64488025
64488028
64488030
64488031
64488032
64488033
64488034
64488035
64488036
64488037
64488038
64538017
64544890
64544891
64544892
64544893
64544894
64544895
64609930
64609931
64609932
64629492
64629494
64629495
64629496
64629518
64629519
64629520
64629522
64629523
64629524
64629525
64629526
64629527
64714907
64714908
64714909
64714912
64714913
64714914
64800035
64800036
64800038
64800041
64800043
64800045
64800047
64800052
64800053
64800054
64800055
64800056
64800057
64800058
64800059
64800060
64800061
64800062
64800077
64800078
64800079
64800080
64800081
64800082
64896819
64896820
64896821
64896823
64896824
64896825
64896826
64896828
64896829
64896846
64896848
64896852
64896853
64896855
64896856
64896858
64896860
64910349
64910350
64910356
64910358
64917592
64917593
64917594
64917595
64917596
64917597
64917598
64917599
64917601
64917602
64917603
64917604
64938529
64938530
64938531
64938532
64938533
64938559
64938595
65021060
65021061
65021062
65021063
65021064
65021065
65021066
65021067
65021068
65021069
65069860
65069861
65069887
65069901
65069902
65241206
65241207
65241208
65305082
65305083
65305084
65305085
65305086
65305087
65305088
65322090
65322092
65328600
65328603
65383773
65383775
65383778
65383779
65383782
65499002
65499005
65521087
65934072
65934073
65977491
65990276
|
| FEI Number |
1000220733
|
Recalling Firm/ Manufacturer |
Zimmer, Inc. 1800 W Center St Warsaw IN 46580-2304
|
| For Additional Information Contact | 411 Technical Services 574-371-3071 |
Manufacturer Reason for Recall | Thread form issue for the locking holes in that the locking screws may not properly mate with the plate. The improperly mated screw may not be readily recognizable by the user since the screw may not correctly lock, may result in delay in surgery or loss of fixation resulting further intervention |
FDA Determined Cause 2 | Under Investigation by firm |
| Action | Zimmer issued Urgent Medical Device Recall Letter to Distributors Risk Managers and Surgeons on March 20, 2024 via mail/email. Letter states reason for recall, health risk and action to take:
Our records indicate that you may have received one or more of the affected products. The affected units were distributed between March 2019 and January 2024.
Risk Manager Responsibilities:
1.
Review this notification and ensure that affected personnel are aware of the contents.
2.
If you have affected product at your facility, assist your Zimmer Biomet sales representative and quarantine all affected product. Your Zimmer Biomet sales representative will remove the affected product from your facility.
3. If the product has been further distributed, provide your customers with the recall notice for hospitals or surgeons and ensure documentation.
4.
Complete Attachment 1 Certificate of Acknowledgement and send to CorporateQuality.PostMarket@zimmerbiomet.com. This form shall be returned even if you do not have affected products at your facility.
5.
Retain a copy of the acknowledgement form with your recall records in the event of a compliance audit of your facility s documentation.
6.
If you have further questions or concerns after reviewing this notice, please call customer service at 574-371-3071 between 8:00 am and 5:00pm EST, Monday through Friday. Calls received outside of call center operating hours will receive a voicemail prompt or be transferred to an on-call representative in the event of an emergency. Alternatively, your questions may be emailed to CorporateQuality.PostMarket@zimmerbiomet.com.
Surgeon Responsibilities:
1.
Review this notification for awareness of the contents.
2.
There are no specific patient monitoring instructions related to this recall that are recommended beyond your existing follow-up schedule.
3.
Complete Attachment 1 Certificate of Acknowledgement and send to CorporateQuality.PostMarket@zimmerbiomet.com.
4.
Retain a copy of the acknowledgeme |
| Distribution | Worldwide distribution - US Nationwide and the countries of Brazil, Canada, China, Hong Kong, India, Japan, New Zealand, Seoul Korea, Singapore, Switzerland, Taiwan.
|
| Total Product Life Cycle | TPLC Device Report |
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls. 2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall. 3 The manufacturer has initiated the recall and not all products have been corrected or removed. This record will be updated as the status changes.
|
| 510(K) Database | 510(K)s with Product Code = HWC
|
|
|
|