| | Class 3 Device Recall Mammotome EX Holster (Product Code HHEX) |  |
| Date Initiated by Firm | December 10, 2004 |
| Date Posted | January 27, 2005 |
| Recall Status1 |
Terminated 3 on October 29, 2008 |
| Recall Number | Z-0440-05 |
| Recall Event ID |
30718 |
| 510(K)Number | K033700 |
| Product Classification |
Instrument, Biopsy - Product Code KNW
|
| Product | Mammotome EX Holster |
| Code Information |
HRDE39904, HRDE40502, HRDE40102, HRDE39920 HRDE40209, HRDE40204, HRDE39916, HRDE40220 HRDE39921, HRDE40114, HRDE40225, HRDE40508 HRDE40210, HRDE40222, HRDE39919, HRDE39906 HRDE40218, HRDE40724, HRDE40109, HRDE39903 HRDE40106, HRDE40118, HRDE40203, HRDE40113 HRDE40511, HRDE40206, HRDE39908, HRDE39910 HRDE40701, HRDE40513, HRDE40713, HRDE40720 HRDE40718, HRDE40710, HRDE40704, HRDE40716 HRDE40706, HRDE40520, HRDE40722, HRDE40708 HRDE40714 HRDE40522, HRDE40719, HRDE40705 HRDE40525, HRDE40527, HRDE40721, HRDE40703 HRDE40516, HRDE40725, HRDE40709, HRDE40702 HRDE40715, HRDE40518, HRDE40506, HRDE40519 HRDE40707, HRDE40712, HRDE40711, HRDE39922 HRDE40103, HRDE39901, HRDE40126, HRDE40120 HRDE39905, HRDE40723, HRDE40101, HRDE40205 HRDE40214, HRDE40526, HRDE40618, HRDE39902 HRDE40202, HRDE40122, HRDE40217, HRDE40221 HRDE40216, HRDE40624, HRDE39924, HRDE40717 HRDE40226, HRDE40503, HRDE40213, HRDE40107 HRDE40110, HRDE40524, HRDE40121, HRDE40514 HRDE39925, HRDE39909, HRDE39912, HRDE40505 HRDE40112, HRDE40212, HRDE40510, HRDE40208 HRDE40201, HRDE39907, HRDE39926, HRDE40124 HRDE40223, HRDE39923, HRDE40219, HRDE40111 HRDE40509, HRDE40515, HRDE40517, HRDE40108 HRDE39918, HRDE40521, HRDE40123, HRDE39914 HRDE39915, HRDE40501, HRDE40211 HRDE40224 HRDE40105, HRDE40207, HRDE39911, HRDE39911, HRDE 39913 |
| FEI Number |
1527736
|
Recalling Firm/ Manufacturer |
Ethicon Endo-Surgery 4545 Creek Rd Cincinnati OH 45242-2803
|
| For Additional Information Contact | Carol Montandon 513-337-3419 |
Manufacturer Reason for Recall | A capacitor of the wrong value was used. The capacitor used was 0.11 microfarad instead of 0.22 microfarad called for in the product specifications. |
FDA Determined Cause 2 | Other |
| Action | The recalling firm notified hospitals and distributors of the product by letter, dated 12/10/04. |
| Quantity in Commerce | 120 devices |
| Distribution | The product was distributed to consignees located in MI, TN, IL, NC, GA, IL, CA, FL, IN, WI, TX, AR, KS, IA, OK, NY, PA, MS, KY, ME, MO, MA, VA, NJ, LA, MN, SD, UT, CO, AL, and NH. There are no foreign consignees. |
| Total Product Life Cycle | TPLC Device Report |
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls. 2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall. 3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 §7.55.
|
| 510(K) Database | 510(K)s with Product Code = KNW
|
|
|
|