• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

Class 2 Device Recall Decade Plus 1221 Dental Chair

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 


New Search Back to Search Results
 Class 2 Device Recall Decade Plus 1221 Dental Chairsee related information
Date Initiated by FirmApril 01, 2009
Create DateJune 25, 2015
Recall Status1 Terminated 3 on December 16, 2010
Recall NumberZ-0541-2011
Recall Event ID 52039
510(K)NumberK913535 
Product Classification chair, dental, with operative unit - Product Code KLC
ProductA-dec Decade Plus 1221 Dental Chair This chair is used for positioning dental patient prior to and during dental treatment.
Code Information Serial Numbers:  A869549, A869550, A869551, A869552, A869553, A869554, A869555, A869556, A869557, A869558, A869559, A870430, A870431, A870432, A870433, A870434, A870435, A870436, A870437, A870439, A870440, A870441, A870442, A870443, A870445, A870446, A870447, A870448, A870449, A870450, A870451, A870452, A870453, A870454, A870455, A870456, A870457, A870458, A870459, A870460, A870461, A870462, A870463, A871279, A871470, A871471, A871472, A871473, A871785, A871786, A871787, A871788, A871789, A871790, A871791, A871792, A871793, A871794, A871795, A871796, A871797, A872250, A872251, A872428, A872429, A872430, A872431, A872432, A872433, A872434, A872435, A872436, A872437, A872438, A872439, A872440, A872441, A872442, A872443, A872444, A872445, A872446, A873967, A873968, A873969, A873970, A873971, A873972, A873973, A873974, A873975, A873976, A873977, A873978, A873979, A873980, A873981, A873982, A874461, A874462, A874463, A874464, A874465, A874466, A874467, A874468, A874469, A874470, A874471, A874472, A874473, A874474, A874475, A874476, A874477, A874478, A875814, A875815, A875816, A875817, A875818, A875819, A875820, A875821, A875822, A875823, A875824, A875825, A875826, A875827, A875828, A875829, A875830, A875831, A875832, A875833, A875834, A875835, A875836, A875837, A875838, A875839, A875840, A875841, A875842, A875843, A875844, A875845, A875846, A875847, A876414, A876415, A876522, A901058, A901065, A901066, A901067, A901068, A901069, A901070, A901075, A901079, A901080, A901083, A901085, A901086, A901087, A901088, A901089, A901090, A901091, A901092, A901093, A901094, A901095, A901096, A901097, A901098, A901099, A901100, A901101, A901102, A901103, A901104, A901105, A902662, A902663, A902664, A902665, A902666, A902667, A902671, A902673, A902674, A902675, A902676, A902677, A902678, A902679, A902680, A902681, A902682, A902683, A902684, A902685, A902686, A902687, A902688, A902689, A902690, A902691, A902692, A902693, A902694, A902695, A902696, A902697, A903478, A903479, A903669, A903670, A998103, A998104, A998105, A998106, A998210, A998211, A998212, A998213, A998214, A998216, A998217, A998218, A998219, A998220, A998221, A998222, A998223, A998224, A998225, A998226, A998227, A998228, A998229, A998230, A998231, A999195, A999196, A999197, A999198, A999199, A999200, A999201, A999202, A999203, A999204, A999205, A999206, A999207, A999208, A999209, A999210, A999211, A999212, A999213, A999214, A999215, A999216, A999217, A999218, A999219, A999220, A999221, A999222, A999223, A999224, A999225, A999226, A999227, A999228, A999229, A999230, A999231, A999232, A999233, A999234, A999235, A999236, A999237, A999238, A999239, A999240, A999241, B878030, B878031, B878032, B878033, B878034, B878035, B878036, B878037, B878038, B878039, B878040, B878041, B878042, B878043, B878044, B878045, B878047, B878048, B878049, B878050, B878051, B878052, B878053, B879437, B879882, B879883, B881271, B881272, B881273, B881274, B881275, B881276, B881277, B881278, B881279, B881280, B881281, B881282, B881283, B881284, B881285, B881286, B881288, B881289, B881290, B881291, B881292, B881293, B881294, B881295, B881296, B881297, B881298, B881299, B881300, B881301, B881302, B881303, B882900, B882901, B882902, B882903, B882904, B882905, B882906, B882907, B882908, B882909, B882910, B882911, B882912, B882913, B882914, B882915, B882916, B882917, B882918, B882919, B882920, B882921, B882922, B882923, B882924, B882925, B882926, B885146, B885148, B885149, B885150, B885151, B885152, B885153, B885154, B885155, B885156, B885157, B885158, B885159, B885160, B885161, B885162, B886394, B886395, B886396, B886398, B886399, B905819, B905820, B905821, B905822, B905823, B905824, B905825, B905826, B905827, B905828, B905829, B905830, B905832, B905833, B905834, B905835, B905836, B905837, B905838, B905839, B905840, B905841, B905842, B905843, B905844, B905845, B905846, B905847, B905848, B905849, B905850, B905946, B905947, B905948, B905949, B906170, B906171, B906172, B906173, B906926, B906927, B906928, B906929, B906930, B906931, B906932, B906933, B906934, B906935, B906936, B906937, B906938, B906939, B906940, B906941, B906942, B906943, B906944, B906945, B906946, B906947, B906948, B906949, B906950, B906951, B906952, B906953, B906954, B906955, B906957, B906958, B908563, B908564, B908565, B908566, B908567, B908568, B908569, B908570, B908571, B908572, B908573, B908574, B908575, B908576, B908577, B908578, B908579, B908581, B908582, B908583, B908584, B908585, B908586, B908587, B908588, B908589, B908590, B908591, B908592, B908593, B908663, B908664, B908665, B909394, B909395, B909396, B909397, B909398, B909399, B909400, B909401, B909402, B909403, B909404, B909405, B909406, B909407, B909408, B909409, B909410, B910496, B910503, B910504, C888619, C888620, C888621, C888622, C888623, C888624, C888625, C888626, C888627, C888628, C888629, C888630, C888631, C888632, C888633, C888634, C888635, C888636, C888637, C888638, C888639, C888640, C889921, C890693, C890694, C890695, C890696, C890697, C890698, C890699, C890700, C890701, C890702, C890703, C890704, C890705, C890706, C890707, C890708, C890709, C890710, C890711, C890712, C890713, C890714, C890715, C890716, C890717, C890718, C890719, C890720, C890721, C890722, C890723, C890724, C890725, C890726, C892670, C892671, C892672, C892673, C892674, C892675, C892676, C892677, C892678, C892679, C892680, C892681, C892682, C892683, C892684, C892685, C892686, C892687, C892688, C892689, C892690, C892691, C892692, C892693, C892694, C892695, C892696, C892697, C892698, C892699, C892700, C893506, C894939, C894940, C894941, C894942, C894943, C894944, C894945, C894946, C894947, C894948, C894949, C894950, C894951, C894952, C894953, C894954, C894955, C894956, C894957, C894958, C894959, C894960, C894961, C894962, C894963, C894964, C894965, C894966, C894967, C894968, C894969, C894971, C894972, C894973, C894974, C894975, C894976, C894979, C896814, C896815, C896816, C896817, C896818, C896819, C896820, C896821, C896822, C896823, C896824, C896825, C910842, C910844, C910845, C910847, C910848, C910849, C910851, C910852, C910853, C910859, C910860, D800048, D800049, D800050, D800051, D800247, D800248, D800249, D800250, D800251, D800252, D800253, D800254, D800255, D800256, D800257, D800258, D800259, D800260, D800261, D800262, D800263, D800264, D800265, D800266, D800267, D800268, D800269, D800270, D800271, D800272, D800273, D800274, D800275, D800276, D801730, D801731, D801732, D801733, D801734, D801735, D801736, D801737, D801738, D801739, D801740, D801741, D801742, D801743, D801744, D801745, D801746, D801747, D801748, D801749, D801750, D801751, D801752, D804130, D804131, D804132, D804133, D804134, D804135, D804136, D804137, D804138, D804140, D804141, D804142, D804143, D804144, D804145, D804146, D804147, D804148, D804149, D804150, D804151, D804152, D804153, D804154, D804156, D804157, D804158, D804159, D804160, D804167, D804168, D804169, D804170, D804171, D804172, D804173, D804174, D804199, D806193, D806194, D806195, D806196, D806197, D806198, D806199, D806200, D806201, D806202, D806203, D806204, D806205, D806206, D806207, D806208, D806209, D806210, D806211, D806212, D806213, D806214, D806215, D806216, D806217, D806218, D806219, D806220, D806221, D806222, D806223, D898026, D898027, D898028, D898029, D898030, D898031, D898032, D898033, D898034, D898035, D898036, D898037, D898038, D898039, D898040, D898041, D898042, D898043, D898044, D898045, D898046, E810482, E810483, E810484, E810485, E810486, E810487, E810488, E810489, E810490, E810491, E810492, E810493, E810494, E810495, E810496, E810497, E810498, E810499, E810500, E810501, E810502, E810503, E810504, E810505, E810506, E810507, E810508, E810509, E810510, E810511, E810512, E810513, E810514, E810515, E810516, E810517, E810518, E810519, E810520, E810521, E810522, E810523, E811611, E811612, E812302, E812303, E812304, E812305, E812306, E812307, E812308, E812309, E812310, E812311, E812312, E812313, E812314, E812315, E812316, E812317, E812318, E812319, E812320, E812321, E812322, E812323, E812324, E812325, E812326, E812327, E812328, E812329, E812330, E812331, E812332, E812333, E812334, E812335, E812336, E812337, E812338, E812339, E812340, E812341, E812342, E812343, E812344, E812345, E812346, E812347, E812348, E812349, E813753, E813754, E814234, E814235, E814236, E814361, E814362, E814363, E814364, E814365, E814366, E814367, E814368, E814369, E814370, E814371, E814372, E814373, E814374, E814375, E814376, E814377, E814378, E814379, E814380, E814381, E814382, E814383, E814384, E814385, E814386, E814387, E814388, E814389, E814390, E814391, E814392, E814393, E814394, E814395, E814396, E814397, E814398, E814982, E814983, E814984, E814985, E814986, E815780, E815781, E816285, E816286, E816287, E816288, E816289, E816290, E816291, E816292, E816293, E816294, E816295, E816296, E816297, E816298, E816299, E816300, E816301, E816302, E816303, E816304, E816305, E816306, E816307, E816308, E816309, E816311, E816312, E816313, E816314, E816315, E816316, E816441, E817144, E817414, E817415, F818944, F818945, F818946, F818947, F818948, F818949, F818950, F818951, F818952, F818953, F818954, F818955, F818956, F818957, F818958, F818959, F818960, F818961, F818962, F818963, F818964, F818965, F818966, F818967, F818968, F818969, F818970, F818971, F818972, F818973, F818974, F818975, F818976, F818977, F818978, F818979, F818980, F818981, F818982, F818983, F818984, F818985, F818986, F818987, F818988, F818989, F818990, F818991, F818992, F818993, F818994, F819881, F819920, F819921, F819922, F819923, F819924, F819925, F819926, F819927, F820912, F820913, F820914, F820915, F820916, F820917, F820918, F820919, F820920, F820921, F820923, F820924, F820925, F820926, F820927, F820928, F820930, F820931, F820932, F820933, F820934, F820935, F820936, F820937, F820938, F820939, F820940, F820941, F820942, F820943, F820944, F820945, F820997, F820998, F821758, F821759, F821760, F821761, F821762, F821763, F821764, F821765, F821766, F821767, F821768, F821769, F821770, F821771, F821772, F821773, F821774, F821775, F821776, F823553, F823554, F823555, F823556, F823557, F823558, F823559, F823560, F823561, F823562, F823563, F823564, F823565, F823566, F823567, F823568, F823569, F823570, F823571, F823572, F823573, F823574, F823575, F823576, F823577, F823578, F823579, F823580, F823822, F823823, F823824, F823825, F825189, F825792, F825793, F825794, F825795, F825796, F825797, F825798, F825799, F825800, F825801, F825802, F825803, F825804, F825805, F825806, F825807, F825808, F825809, F825810, F825811, F825812, F825813, F825814, F825815, F825816, F825817, F825818, F825819, F825820, F825821, F825822, F825823, F825828, F825829, F825830, F832952, F832953, F832954, F832955, F832956, F833267, F833268, F833269, F833270, F833271, F833272, F833273, F833274, F833275, F833276, F833280, F833281, F833282, F834197, F834198, F834199, F834200, F834201, F834202, F834203, F834204, F834205, F834206, F834207, F834208, F834209, F834210, F834211, G834666, G834667, G834668, G834669, G834670, G834671, G834672, G834673, G835641, G835642, G835643, G835644, G835645, G835646, G835647, G835648, G835649, G835650, G835651, G835652, G835653, G835654, G835655, G835656, G835657, G835658, G835659, G835660, G835661, G835662, G835663, G835664, G835665, G835666, G835667, G835668, G835669, G835670, G835671, G835672, G835673, G835674, G835675, G835676, G835677, G835678, G835679, G835680, G835681, G835682, G835683, G836684, G836685, G836686, G836687, G836688, G836689, G836690, G836691, G838897, G838898, G838899, G838900, G838901, G838902, G838903, G838904, G838905, G838906, G838907, G838908, G838909, G838910, G838911, G838912, G838913, G838914, G838915, G838916, G838917, G838918, G838919, G838920, G838921, G838922, G838923, G838924, G838925, G838926, G838927, G838928, G838929, G838930, G838931, G838932, G838933, G838934, G838935, G838936, G838937, G838938, G838939, G838940, G838941, G841666, G841667, G841668, G841669, G841670, G841671, G841672, G841673, G841674, G841675, G841676, G841677, G841678, G841679, G841680, G841681, G841682, G841683, G841684, G841685, G841686, G841687, G841688, G841689, G841690, G841691, G841692, G841693, G841694, G841695, G841696, G841697, G841698, G841699, G841700, G841701, G841702, G841703, G841704, G843256, G843257, G843258, G843259, G843260, G843261, G843262, G843263, G843264, G843265, G843266, G843267, G843268, G843269, G843270, G843271, G843272, G843273, G843274, G843275, G843276, G843277, G843278, G843279, G843280, G843281, G843282, G843283, G843284, G843285, G843286, G843287, G843288, G845459, G845460, G845461, G845462, G845463, G845464, G845465, G845466, G845467, G845468, G845469, H846761, H846762, H846763, H846764, H846765, H846766, H846767, H846768, H846769, H846770, H846771, H846772, H846773, H846774, H846775, H846776, H846777, H846778, H846779, H846780, H846781, H846782, H846783, H846784, H846785, H846786, H846787, H846788, H848658, H848659, H848660, H848661, H849166, H849167, H849168, H849169, H849170, H849171, H849172, H849173, H849174, H849175, H849176, H849177, H849178, H849179, H849180, H849181, H849182, H849183, H849184, H849185, H849186, H849187, H849188, H849189, H849190, H849191, H849192, H849193, H849194, H849195, H849196, H849197, H849198, H849199, H849200, H849201, H849202, H849203, H849204, H849205, H849206, H849207, H849208, H849209, H849210, H849211, H849212, H849213, H849214, H849215, H849216, H849217, H849218, H849219, H849220, H850911, H850912, H850913, H850914, H850915, H850916, H850917, H850918, H850919, H850920, H850921, H850922, H850923, H850924, H850925, H850926, H850927, H850928, H850929, H850930, H850931, H850932, H850933, H850934, H850935, H850936, H850937, H850938, H850939, H850940, H850941, H850942, H850943, H850944, H850945, H850946, H850947, H850948, H850949, H850950, H850951, H850952, H850953, H850954, H850955, H850956, H850957, H850958, H850959, H850960, H850961, H850962, H851151, H851170, H851171, H851172, H851173, H851174, H851175, H853399, H853400, H853401, H853402, H853403, H853404, H853405, H853406, H853407, H853408, H853409, H853410, H853411, H853412, H853413, H853414, H853415, H853416, H853417, H853418, H853419, H853420, H853421, H853422, H853423, H853424, H853425, H853426, H853427, H853428, H853429, H853430, H853431, H853432, H853433, H853434, H853435, H853436, H853437, H853438, H853963, H853964, H853965, H853966, H853967, H853968, H853969, H853970, H853971, H853972, H853973, H853974, H853975, H853976, H853977, H855652, H855653, H855654, H855655, H855656, H855657, H855658, H855659, H855660, I856261, I856262, I856263, I856264, I856265, I856266, I856267, I856268, I856269, I856270, I856271, I856272, I856273, I856274, I856275, I856276, I856277, I856278, I856279, I856280, I856281, I856282, I856283, I856284, I856285, I859145, I859146, I859147, I859148, I859149, I859150, I859151, I859152, I859153, I859154, I859155, I859156, I859157, I859158, I859159, I859160, I859161, I859162, I859163, I859164, I859165, I859166, I859167, I859168, I859169, I859170, I859171, I859172, I859173, I859174, I859175, I859176, I859177, I859178, I859179, I859180, I859181, I859182, I859183, I859184, I859185, I859186, I859187, I859188, I859189, I859190, I859191, I859192, I859194, I859195, I859196, I859197, I859198, I859199, I859200, I859316, I859317, I859318, I859319, I859320, I859321, I859322, I859323, I859324, I859325, I859683, I861189, I861190, I861191, I861192, I861193, I861194, I861195, I861196, I861197, I861198, I861199, I861200, I861201, I861202, I861203, I861204, I861205, I861206, I861207, I861208, I861209, I861210, I861211, I861212, I861213, I861214, I861215, I861216, I861217, I861218, I861219, I861220, I861221, I861222, I861223, I861224, I861225, I861226, I861227, I861228, I861229, I861230, I861231, I861232, I861233, I861234, I861235, I861236, I861237, I861238, I861239, I861240, I861241, I861242, I861243, I861244, I861245, I861590, I861591, I861592, I861593, I863485, I863487, I863488, I863489, I863490, I863491, I863492, I863493, I863494, I863495, I863496, I863497, I863498, I863499, I863500, I863501, I863502, I863503, I863504, I863505, I863506, I863507, I863508, I863509, I863510, I863511, I863513, I863514, I863944, I863945, I863947, I865262, I865616, I865617, I865619, I865620, I865621, I865622, I865623, I865624, I865625, I865626, I865627, I865628, I865629, I865630, I865631, I865632, I865633, I865634, I865635, I865636, I865637, I865638, I865639, I865640, I865641, I865642, I865643, I865644, I865645, I865646, I865647, I865648, I865649, I865650, I865651, I865652, I865653, I865654, I865655, I865656, I865657, I865658, I865659, I865660, I866799, I866800, I866801, I866802, J868668, J868669, J868670, J868671, J868672, J868673, J868674, J868675, J868676, J868677, J868678, J868791, J868792, J868793, J868794, J868795, J869541, J869542, J869543, J869544, J869740, J869741, J869742, J869743, J869744, J869745, J869746, J869747, J869748, J869749, J869750, J869751, J869752, J869753, J869754, J869755, J869756, J869757, J869758, J869759, J869760, J869761, J869762, J869763, J869764, J869765, J869766, J869767, J869768, J869769, J869770, J869771, J869772, J869773, J869774, J869775, J869776, J869777, J869778, J869779, J869780, J869781, J869782, J869783, J869784, J869785, J869786, J869787, J869788, J869789, J869790, J869791, J869792, J869793, J869794, J869795, J869796, J869797, J869798, J869799, J869800, J869801, J871351, J871352, J871353, J871354, J871539, J871540, J871541, J871542, J871543, J871544, J871545, J871546, J871547, J871548, J871549, J871550, J871551, J871552, J871553, J871554, J871555, J871556, J871557, J871558, J871559, J871560, J871561, J871562, J871563, J871564, J871565, J871566, J871567, J871569, J871570, J871571, J871573, J871590, J871591, J871592, J871593, J871594, J871595, J871596, J871597, J872031, J872032, J872033, J872034, J872035, J872036, J872037, J872038, J872039, J872040, J872813, J872814, J872815, J872816, J872817, J872818, J872819, J872820, J873380, J873381, J873382, J873383, J873384, J873385, J873386, J873387, J873388, J873389, J873390, J873391, J873392, J873393, J873394, J873395, J873396, J873397, J873398, J873399, J874107, J874109, J874110, J874111, J874112, J874113, J874114, J874115, J874116, J874117, J874118, J874119, J874120, J874121, J874122, J874123, J874124, J874125, J874126, J874127, J874128, J874129, J874130, J874131, J874132, J874133, J874134, J874135, J874136, J874137, J874138, J874139, J874140, J874141, J874142, J874143, J874144, J874145, J874146, J874147, J874148, J874149, J874150, J874151, J874152, J874153, J874154, J874155, J874156, J874157, J874158, J874159, J874160, J874161, J874834, J876351, J876352, J876353, J876354, J876355, J876356, J876357, J876358, J876359, J876360, J876361, J876362, J876364, J876369, J876370, J876371, J876372, J876373, J876374, J876375, J876376, J876379, J876380, J876381, J876382, J876397, J876398, J876399, J876400, J876401, J876643, J876644, J876828, J876829, J876830, J876831, J876832, J876833, J876834, J876835, J876836, J876837, J877184, J877185, J877186, J877187, J877188, J877189, J877190, J877191, J877228, J877229, J877230, J877231, J877232, J877233, J877235, J877236, J877237, J877238, J877239, J877240, J877241, J877242, J877243, J877244, J877245, J877246, J877247, J877248, J877249, J877250, J877251, J877252, J877253, J877254, J877255, J877256, J877257, J877258, J877259, J877260, J877261, J877262, J877263, J877264, J877265, J877266, J877267, J877268, J877269, J878388, J878389, J878390, J878391, J878392, J878393, J878394, K752834, K753196, K753197, K753198, K755502, K755503, K755504, K755505, K755506, K755507, K755508, K755509, K755510, K755511, K755512, K755513, K755514, K755515, K755516, K755517, K755518, K755519, K755520, K755521, K755522, K755523, K755524, K755525, K755526, K756648, K756649, K756650, K756651, K756652, K756653, K756654, K756655, K756656, K756657, K756658, K756659, K756660, K756661, K756662, K756663, K756664, K756665, K756666, K756667, K756668, K756669, K756670, K756671, K756672, K879009, K879010, K879011, K879012, K879013, K879014, K879015, K879016, K879017, K879018, K879019, K879020, K879021, K879022, K879023, K879024, K879025, K879026, K879027, K879028, K879029, K880754, K880755, K880756, K880757, K880758, K880759, K881320, K881321, K881322, K881323, K881850, K881851, K881852, K881853, K881854, K881855, K881856, K881857, K881858, K881859, K881860, K881861, K881862, K881863, K881864, K881865, K881866, K881867, K881868, K881869, K881870, K881871, K881872, K881873, K881874, K881875, K881876, K881877, K881878, K881879, K882106, K882107, K882108, K882109, K882110, K882111, K882112, K882113, K882114, K882115, K882116, K882117, K882118, K882119, K882120, K882121, K882122, K882123, K882124, K882125, K882126, K882127, K882128, K882129, K882130, K882131, K882132, K882133, K882134, K882135, K882136, K882137, K882138, K882139, K882140, K882141, K882142, K882143, K882144, K882145, K882146, K882147, K882148, K882149, K882150, K882151, K882152, K882153, K882154, K882155, K884060, K884061, K884062, K884063, K884064, K884065, K884066, K884067, K884068, K884069, K884070, K884071, K884072, K884073, K884074, K884075, K884076, K884087, K884088, K884089, K884090, K884096, K884097, K884098, K884099, K884100, K884101, K884102, K884103, K884104, K884105, K884106, K884107, K884108, K884109, K884110, K884111, K884112, K884113, K884114, K884115, K884116, K884117, K884118, K884119, K884120, K884121, K884122, K884123, K884124, K884125, K884126, K884127, K884524, K884525, K884526, K884527, K884528, K884529, K884530, K884531, K884532, K884533, K884534, K884535, K884536, K884537, K884538, K884539, K884546, K884547, K884548, K884549, K884735, K884736, K884737, K884738, K884739, K884740, K884741, K884742, K884743, K884744, K884745, K885464, K886610, K886611, K886612, K886613, K886614, K886615, K886616, K886617, K886618, K886619, K886620, K886621, K886622, K886623, K886624, K886625, K886626, K886627, K886628, K886629, K886630, K886631, L758869, L758870, L758871, L758872, L758873, L758874, L758875, L758876, L758877, L758878, L758879, L758880, L758881, L758882, L758883, L758884, L758885, L758886, L758887, L758888, L758889, L758890, L758891, L758892, L758893, L761759, L761761, L761762, L761763, L761764, L761765, L761766, L761767, L761768, L761769, L761770, L761771, L761772, L761773, L761774, L761775, L761776, L761777, L761778, L761779, L761780, L761781, L761782, L761783, L761784, L763628, L763629, L763630, L763631, L763632, L763638, L765155, L765156, L765157, L765158, L765204, L765205, L765206, L765207, L765208, L765209, L765210, L765211, L765212, L765213, L765214, L765215, L765216, L765217, L765218, L765219, L765220, L765221, L765222, L765223, L765224, L765225, L765226, L765227, L765228, L765229, L765230, L765231, L765232, L765233, L765234, L765235, L765236, L765237, L765238, L765239, L765240, L765241, L765242, L765243, L765244, L765245, L765246, L765247, L765248, L765249, L765250, L765251, L765252, L765253, L765254, L765255, L765256, L765257, L765258, L765259, L889839, L889840, L889841, L889842, L889843, L889844, L889845, L889846, L889847, L889848, L889849, L889850, L889851, L889852, L889853, L889854, L889855, L889856, L889857, L889858, L889859, L889860, L889861, L889862, L889863, L889864, L889865, L889866, L889867, L889868, L889869, L889870, L889871, L889873, L889874, L889875, L889876, L889877, L889878, L889945, L890520, L890521, L890522, L890523, L890524, L890525, L890526, L890527, L890528, L890529, L890918, L890919, L890920, L890921, L890922, L890923, L890924, L890925, L890926, L890927, L890928, L890929, L890930, L890931, L890932, L890933, L890934, L890935, L890936, L890937, L890938, L890939, L890940, L890941, L891680, L891681, L891682, L891683, L892173, L892174, L892175, L892176, L892177, L892178, L892179, L892180, L892181, L892182, L892183, L892184, L892185, L892186, L892187, L892188, L892189, L892190, L892191, L892192, L892618, L892619, L892620, L892621, L892622, L892623, L892624, L892625, L892626, L892627, L892628, L892629, L892630, L892631, L892632, L892633, L892634, L892635, L892636, L892637, L892638, L892639, L892640, L892641, L892642, L892643, L892644, L892645, L892646, L892647, L892648, L892649, L892650, L892651, L892652, L892934, L892936, L892937, L892938, L892939, L892940, L892941, L894280, L894281, L894282, L894283, L894284, L894285, L894286, L894287, L894288, L894289, L894290, L894291, L894292, L894293, L894294, L894295, L894296, L894297, L894298, L894300, L894301, L894302, L894667, L894796, L894797, L895163, L895164, L895165, L895166, L895167, L895488, L895489, L895490, L895491, L895492, L895493, and L895494.
FEI Number 3015729
Recalling Firm/
Manufacturer
A-Dec Inc
2601 Crestview Dr
Newberg OR 97132
For Additional Information ContactCustomer Service
800-547-1883
Manufacturer Reason
for Recall
The design of the Decade Plus 1221 chair backrest creates a possible pinch-point between the chair backrest and the underside of the armrests.
FDA Determined
Cause 2
Device Design
ActionA-dec sent a letter dated March 23, 2009 to consignees/customers (doctors and network dealers). The consignees were informed that the design of the Decade Plus 1221 chair backrest creates a possible pinch-point between the chair backrest and the underside of the armrests. The potential for this occurs when returning the chair to the upright position. The consignees were advised to reprogram the Position 0/Entry-Exit preset to stop the back before it reaches a full upright position. This increases the gap between the armrest and the back slightly. To reprogram a chair, the firm included excerpts from a chair Instructions for Use (IfU) guide that detail the steps to reprogram a chair. Consignees can contact the firm's Customer Service at 503-538-9471, 1-800-547-1883, or via fax at 503-538-0276. The firm will replace the chair back assembly for all affected dental chairs.
Quantity in Commerce2723 units
DistributionWorldwide distribution: US and Canada.
Total Product Life CycleTPLC Device Report

1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls.
2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall.
3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 §7.55.
510(K) Database510(K)s with Product Code = KLC
-
-