| | Class 2 Device Recall Palindrome Precision HSI Chronic Catheter Sport Pack w/VenaTrac Stylet |  |
| Date Initiated by Firm | April 23, 2015 |
| Date Posted | July 01, 2015 |
| Recall Status1 |
Terminated 3 on July 26, 2017 |
| Recall Number | Z-1911-2015 |
| Recall Event ID |
70985 |
| 510(K)Number | K062671 K112477 K123196 |
| Product Classification |
Catheter, hemodialysis, implanted - Product Code MSD
|
| Product | Palindrome Precision HSI Chronic Catheter Sport Pack w/VenaTrac Stylet 14.5 Fr x 33cm
Item Code: 8888133509P |
| Code Information |
Item codes identified with an expiry date of February 2018 and earlier |
| FEI Number |
1219930
|
Recalling Firm/ Manufacturer |
Covidien LLC
60 Middletown Ave
North Haven
CT
06473-3908
|
| For Additional Information Contact | 203-492-5000 |
Manufacturer Reason for Recall | Catheters may not meet antimicrobial specification |
FDA Determined Cause 2 | Nonconforming Material/Component |
| Action | Medtronic (Covidien) issued recalll letter dated April 24, 2015, via FedEx overnight delivery to all affected customers. Customers were requested to quarantine and discontinue use of the affected devices. Customers were instructed to complete A Recalled Product Return Form for product returns. Customer Service will respond with a Return Goods Authorization (RGA) number and shipping documents
Customers with questions were instructed to contact their Medtronic representative or Medtronic Customer Service, Monday through Friday, 8am 6:30pm ET, at (800)-882-5878.
For questions regarding this recall call 203-492-5000. |
| Quantity in Commerce | 72,363 US - 24,631 Internationally |
| Distribution | Worldwide Distribution - US (nationwide) and Internationally to Argentina, Austria, Belgium, Brazil, Canada, Chile, China, Czech Republic, Denmark, Ecuador, Egypt, Finland, France, Germany, Greece, Hong, Kong, India, Iran, Ireland, Israel, Italy, Libya, Luxembourg, Malaysia, Mexico, Morocco, Netherlands, Norway, Oman, Panama, Philippines, Poland, Portugal, Saudi Arabia, Singapore, Slovakia, South Africa, Spain, Sweden, Switzerland, Turkey, Thailand, UAE, and United Kingdom. |
| Total Product Life Cycle | TPLC Device Report |
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls. 2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall. 3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 �7.55.
|
| 510(K) Database | 510(K)s with Product Code = MSD 510(K)s with Product Code = MSD
|
|
|
|