| Date Initiated by Firm | October 10, 2025 |
| Date Posted | November 13, 2025 |
| Recall Status1 |
Open3, Classified |
| Recall Number | Z-0448-2026 |
| Recall Event ID |
97882 |
| 510(K)Number | K213481 |
| Product Classification |
General surgery tray - Product Code LRO
|
| Product | Convenience Kits:
DYNJ901048N ORTHO SPINE ST CLAIR
DYNJ909123F UROLOGY MINOR
DYNJ909132F SET UP
DYNJ909308D HIP PINNING |
| Code Information |
HIP PINNING
DYNJ909308D
UDI-DI 40198459055288 (case), 10198459055287 (ea)
Lots
25FBB311
25GBC282
25GBW486;
ORTHO SPINE ST CLAIR
DYNJ901048N
UDI-DI 40198459055554 (case), 10198459055553 (ea)
Lots
25GBQ070;
SET UP
DYNJ909132F
UDI-DI 40198459130572 (case), 10198459130571 (ea)
Lots
25GBI845
25IBF708;
UROLOGY MINOR
DYNJ909123F
UDI-DI 40198459130602 (case), 10198459130601 (ea)
Lots
25GBT826
25IBF707
|
| FEI Number |
1417592
|
Recalling Firm/ Manufacturer |
Medline Industries, LP
3 Lakes Dr
Northfield
IL
60093-2753
|
| For Additional Information Contact | Haley Barclay 866-359-1704 |
Manufacturer Reason for Recall | Firm received multiple complaints of anesthesia circuit leaks due to cracks in the 120" expandable tubing. Cracks and resulting leaks may lead to hypoxia, hypoventilation, and inadequate delivery of inhaled anesthetic agents, which may result in serious injury or death. Volatile anesthetics may also escape into the operating room environment. |
FDA Determined Cause 2 | Nonconforming Material/Component |
| Action | Safety notice was provided to customers on 10/10/2025. Follow-up "URGENT MEDICAL DEVICE RECALL" notification dated 10/21/2025 was sent out on 10/21/2025. Notification was through email and first-class mail.
Customers were instructed to Immediately check your stock for the affected item number(s) and the affected lot number(s) listed within the recall portal. Quarantine all affected product and destroy affected kits on hand. No products are to be returned to Medline.
Please use the link and the information below to complete your response form. Please list the quantity of affected product you have in inventory on the form. Even if you do not have any affected product in inventory, please complete and submit the response form.
Website link: https://recalls.medline.com
Recall Reference #: R-25-215-FG
Recall Code:
If you are a distributor or have resold or transferred this product to another company or individual, you are required by FDA regulations to notify them of this recall communication. Please request that customers destroy any affected product. You should include your customers quantities on your response form.
An expanded "URGENT MEDICAL DEVICE RECALL" notification dated 10/24/2025 was provided to customers on 10/24/25, which included additional affected products.
If you have any questions, contact the Recall Department at 866-359-1704 or recalls@medline.com. |
| Quantity in Commerce | 96,406 total units |
| Distribution | International distribution to Mexico and Panama. US nationwide distribution to the following: AK
AL
AR
AZ
CA
CO
CT
FL
GA
IA
IL
IN
KS
KY
MA
ME
MI
MN
MO
MS
MT
NC
NJ
NY
OH
OR
PA
PR
RI
SC
TN
TX
WA
WI;
|
| Total Product Life Cycle | TPLC Device Report |
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls. 2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall. 3 The manufacturer has initiated the recall and not all products have been corrected or removed. This record will be updated as the status changes.
|
| 510(K) Database | 510(K)s with Product Code = LRO
|