• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

Recognized Consensus Standards: Medical Devices

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

New Search Back To Search Results
Part B: Supplementary Information Sheet (SIS)
FR Recognition List Number 066 Date of Entry 05/25/2026 
FR Recognition Number 13-157
Standard
IEEE  Std 11073-10207-2017 [Including Cor 1-2025]
Health informatics - Point-of-care medical device communication Part 10207: Domain Information and Service Model for Service-Oriented Point-of-Care Medical Device Communication [Including Corrigendum 1 (2025)]
Scope/Abstract
The IEEE 11073-10207-2017 standard falls within the context of the ISO/IEEE 11073 family of standards for point-of-care medical device communication. In this standard, a Participant Model is derived from the ISO/IEEE 11073-10201 Domain Information Model. The Participant Model specifies the structure of medical information objects. Additionally, the standard defines an abstract Communication Model to facilitate the exchange of medical information objects. Both the Participant Model and Communication Model elements are specified using XML Schema. The core subjects covered by the Participant Model include the modeling of medical device-related data (such as measurements and settings), alert systems, contextual information (such as patient demographics and location), remote control, and archival information. XML Schema is utilized to provide extensibility to the model. The corrigendum for this standard comprises fixes related to definition terms, requirements, and a significant retrofit of the versioning concept. It ensures that the standard remains accurate and up-to-date, addressing any issues that may have arisen since its initial publication.
Extent of Recognition
Complete standard
Rationale for Recognition
This standard is relevant to medical devices and is recognized on its scientific and technical merit and/or because it supports existing regulatory policies.

Note: An IEEE Technical Corrigendum is an official supplementary document used to correct technical errors, ambiguities, or omissions inadvertently introduced into an existing IEEE standard. Due to the level of technical changes covered in Corrigendum 1 (2025), recognition of this updated standard has been processed as a new version of an existing recognized standard with a transition period applied.
Transition Period
FDA recognition of IEEE Std 11073-10207-2017 [Rec# 13-106] will be superseded by recognition of IEEE Std 11073-10207-2017/Cor 1-2025 [Rec# 13-157]. FDA will accept declarations of conformity, in support of premarket submissions, to [Rec# 13-106] until July 2, 2028. After this transition period, declarations of conformity to [Rec# 13-106] will not be accepted.
Relevant FDA Guidance and/or Supportive Publications*
1. Design Considerations and Pre-market Submission Recommendations for Interoperable Medical Devices - Guidance for Industry and Food and Drug Administration Staff, issued September 2017.
2. Content of Premarket Submissions for Device Software Functions - Guidance for Industry and Food and Drug Administration Staff, issued 2023.
3. Off-The-Shelf Software Use in Medical Devices - Guidance for Industry and Food and Drug Administration Staff, issued August 2023.
4. Medical Device Data Systems, Medical Image Storage Devices, and Medical Image Communications Devices - Guidance for Industry and Food and Drug Administration Staff, issued September 2022.
5. Cybersecurity in Medical Devices: Quality Management System Considerations and Content of Premarket Submissions, Guidance for Industry and Food and Drug Administration Staff, issued February 2026.
6. Postmarket Management of Cybersecurity in Medical Devices - Guidance for Industry and Food and Drug Administration Staff, issued December 2016.
7. Policy for Device Software Functions and Mobile Medical Applications - Guidance for Industry and Food and Drug Administration Staff, issued September 2022.
8. General Principles of Software Validation - Guidance for Industry and FDA Staff, issued January 2002.
Appropriate Use of Voluntary Consensus Standards in Premarket Submissions for Medical Devices - Guidance for Industry and Food and Drug Administration Staff, issued September 2018.
FDA Technical Contacts
 Sajjad Syed
  FDA/OC/CDRH/OPEQ/ORP/DRPIV/
  301-796-6295
  sajjad.syed@fda.hhs.gov
 Konstantinos Makrodimitris
  FDA/OC/CDRH/OSPTI/ORR/DSCA/
  301-796-6946
  konstantinos.makrodimitris@fda.hhs.gov
 Anil Kochhar
  FDA/OC/CDRH/OPEQ/OHTIII/DHTIIIA/
  301-796-2215
  anil.kochhar@fda.hhs.gov
Standards Development Organization
IEEE Institute of Electrical and Electronic Engineers https://www.ieee.org/
FDA Specialty Task Group (STG)
Software/Informatics
*These are provided as examples and others may be applicable.
-
-