Device
calculator, predicted values, pulmonary function
Product Code
BTY
Regulation Number
868.1890
Device Class
2
Premarket Reviews
Manufacturer
Decision
COSMED SRL
SUBSTANTIALLY EQUIVALENT
1
ERESEARCHTECHNOLOGY GMBH
SUBSTANTIALLY EQUIVALENT
3
GUANGZHOU HOMESUN MEDICAL TECHNOLOGY CO., LTD
SUBSTANTIALLY EQUIVALENT
1
MEDICAL GRAPHICS CORPORATION
SUBSTANTIALLY EQUIVALENT
1
NDD MEDIZINTECHNIK AG
SUBSTANTIALLY EQUIVALENT
1
SHAPE MEDICAL SYSTEMS, INC
SUBSTANTIALLY EQUIVALENT
1
VIRTUS TECHNOLOGY APS
SUBSTANTIALLY EQUIVALENT
1
VITALOGRAPH IRELAND LTD.
SUBSTANTIALLY EQUIVALENT
1
MDR Year
MDR Reports
MDR Events
2015
51
51
2016
24
24
2017
9
9
2018
5
5
2019
3
3
2020
3
3
2021
2
2
2022
2
2
2023
1
1
2024
2
2
Device Problems
MDRs with this Device Problem
Events in those MDRs
High Test Results
27
27
Device Stops Intermittently
11
11
Calibration Problem
8
8
Smoking
7
7
Break
6
6
Overheating of Device
3
3
Failure to Calibrate
3
3
Connection Problem
3
3
Device Operational Issue
3
3
Incorrect, Inadequate or Imprecise Result or Readings
3
3
Temperature Problem
2
2
Device Displays Incorrect Message
2
2
Loose or Intermittent Connection
2
2
Incorrect Software Programming Calculations
2
2
Melted
2
2
Computer Operating System Problem
2
2
Failure to Power Up
2
2
Incorrect Or Inadequate Test Results
2
2
Battery Problem
2
2
Sparking
2
2
Device Operates Differently Than Expected
2
2
Patient Device Interaction Problem
1
1
Defective Device
1
1
Charred
1
1
Patient Data Problem
1
1
Gas/Air Leak
1
1
Output Problem
1
1
Thermal Decomposition of Device
1
1
Application Program Problem: Dose Calculation Error
1
1
Mechanical Problem
1
1
Environmental Compatibility Problem
1
1
Misconnection
1
1
Fumes or Vapors
1
1
Grounding Malfunction
1
1
Computer Software Problem
1
1
Power Problem
1
1
Incorrect Measurement
1
1
Electrical /Electronic Property Problem
1
1
Programming Issue
1
1
Environmental Particulates
1
1
Electrical Power Problem
1
1
Detachment Of Device Component
1
1
Component Falling
1
1
Application Program Problem
1
1
Low Test Results
1
1
Patient Problems
MDRs with this Patient Problem
Events in those MDRs
No Known Impact Or Consequence To Patient
42
42
No Patient Involvement
24
24
No Consequences Or Impact To Patient
16
16
No Clinical Signs, Symptoms or Conditions
7
7
No Information
4
4
Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available
1
1
Fatigue
1
1
Red Eye(s)
1
1
Dizziness
1
1
Malaise
1
1
Irritation
1
1
Injury
1
1
Insufficient Information
1
1
Hypoglycemia
1
1
Fainting
1
1
Thromboembolism
1
1
Recalls
Manufacturer
Recall Class
Date Posted
1
NDDd Medical Technologies, Inc.
II
Dec-03-2019
2
Shape Medical Systems, Inc
II
Feb-05-2015
-
-