Device
probe, thermodilution
Product Code
KRB
Regulation Number
870.1915
Device Class
2
Premarket Reviews
Manufacturer
Decision
PULSION MEDICAL SYSTEMS SE
SUBSTANTIALLY EQUIVALENT
1
MDR Year
MDR Reports
MDR Events
2017
24
24
2018
18
18
2019
26
26
2020
16
16
2021
22
22
2022
21
21
2023
13
13
2024
9
9
Device Problems
MDRs with this Device Problem
Events in those MDRs
Break
35
35
Material Fragmentation
28
28
Leak/Splash
25
25
Incorrect Measurement
10
10
Difficult to Insert
8
8
Crack
8
8
Uncoiled
6
6
Adverse Event Without Identified Device or Use Problem
6
6
Incorrect, Inadequate or Imprecise Result or Readings
4
4
Sticking
4
4
Material Rupture
3
3
Entrapment of Device
3
3
Material Integrity Problem
3
3
Connection Problem
3
3
Fluid/Blood Leak
2
2
Fracture
2
2
Appropriate Term/Code Not Available
2
2
False Reading From Device Non-Compliance
1
1
Disconnection
1
1
Device Alarm System
1
1
Retraction Problem
1
1
Misconnection
1
1
Unable to Obtain Readings
1
1
Delamination
1
1
Device Operates Differently Than Expected
1
1
Improper Device Output
1
1
Manufacturing, Packaging or Shipping Problem
1
1
Material Twisted/Bent
1
1
Mechanical Jam
1
1
Packaging Problem
1
1
Insufficient Information
1
1
Improper or Incorrect Procedure or Method
1
1
Incomplete or Missing Packaging
1
1
Failure to Advance
1
1
Split
1
1
Physical Resistance
1
1
Defective Device
1
1
Malposition of Device
1
1
Patient Problems
MDRs with this Patient Problem
Events in those MDRs
No Consequences Or Impact To Patient
52
52
No Clinical Signs, Symptoms or Conditions
50
50
No Known Impact Or Consequence To Patient
19
19
Foreign Body In Patient
7
7
Insufficient Information
4
4
Device Embedded In Tissue or Plaque
4
4
Ischemia
4
4
Hemorrhage/Bleeding
3
3
Infarction, Cerebral
2
2
No Information
2
2
No Patient Involvement
2
2
Vascular Dissection
2
2
Hematoma
1
1
Air Embolism
1
1
Occlusion
1
1
Thrombosis
1
1
Sudden Cardiac Death
1
1
Recalls
Manufacturer
Recall Class
Date Posted
1
ICU Medical, Inc.
II