Quick Links: Skip to main page content
Skip to Search
Skip to Topics Menu
Skip to Common Links
U.S. Food & Drug Administration
Follow FDA
En Español
Search FDA
Home
Food
Drugs
Medical Devices
Radiation-Emitting Products
Vaccines, Blood & Biologics
Animal & Veterinary
Cosmetics
Tobacco Products
TPLC - Total Product Life Cycle
FDA Home
medical devices
databases
-
510(k)
|
DeNovo
|
Registration & Listing
|
Adverse Events
|
Recalls
|
PMA
|
HDE
|
Classification
|
Standards
CFR Title 21
|
Radiation-Emitting Products
|
X-Ray Assembler
|
Medsun Reports
|
CLIA
|
TPLC
New Search
show TPLC since
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
Back to Search Results
Device
stent, metallic, expandable, duodenal
Regulation Description
Esophageal prosthesis.
Product Code
MUM
Regulation Number
878.3610
Device Class
2
Premarket Reviews
Manufacturer
Decision
TAEWOONG MEDICAL CO., LTD.
SUBSTANTIALLY EQUIVALENT
2
MDR Year
MDR Reports
MDR Events
2021
70
70
2022
28
28
2023
53
55
2024
34
36
2025
32
32
Device Problems
MDRs with this Device Problem
Events in those MDRs
Adverse Event Without Identified Device or Use Problem
52
54
Break
47
47
Migration
38
38
Fracture
30
30
Activation Failure
19
20
Material Deformation
19
19
Positioning Failure
14
14
Premature Activation
12
12
Positioning Problem
10
10
Improper or Incorrect Procedure or Method
9
9
Material Twisted/Bent
9
9
Activation, Positioning or Separation Problem
7
7
Partial Blockage
7
7
Device Stenosis
6
7
Difficult to Remove
6
6
Use of Device Problem
6
6
Insufficient Information
5
5
Migration or Expulsion of Device
4
4
Off-Label Use
4
4
Complete Blockage
4
6
Detachment of Device or Device Component
4
4
Appropriate Term/Code Not Available
3
3
Failure to Advance
3
3
Defective Device
3
3
Device Damaged Prior to Use
3
3
Physical Resistance/Sticking
3
3
Structural Problem
2
2
Material Perforation
2
2
Material Integrity Problem
2
2
Material Separation
2
2
Unsealed Device Packaging
2
2
Difficult to Advance
2
2
Collapse
2
3
Premature Separation
2
2
Difficult or Delayed Positioning
1
1
Obstruction of Flow
1
1
Packaging Problem
1
1
Poor Visibility
1
1
Retraction Problem
1
1
No Apparent Adverse Event
1
1
Activation Problem
1
1
Human-Device Interface Problem
1
1
Deformation Due to Compressive Stress
1
1
Entrapment of Device
1
1
Patient Problems
MDRs with this Patient Problem
Events in those MDRs
No Clinical Signs, Symptoms or Conditions
113
113
Obstruction/Occlusion
37
39
Insufficient Information
15
17
Hemorrhage/Bleeding
14
16
Perforation
13
13
Erosion
11
13
Vomiting
11
12
Stenosis
9
9
Gastrointestinal Hemorrhage
6
6
No Information
6
6
Abdominal Pain
5
5
Pneumonia
5
5
Nausea
4
4
Inflammation
4
4
Fever
4
5
Pancreatitis
3
3
Occlusion
3
3
Bowel Perforation
3
3
Aspiration/Inhalation
3
3
Restenosis
2
2
Constipation
2
2
No Consequences Or Impact To Patient
2
2
Feeding Problem
2
2
Pain
2
2
Thrombosis/Thrombus
2
4
Foreign Body In Patient
2
2
No Known Impact Or Consequence To Patient
2
2
Cardiac Arrest
2
3
Abdominal Distention
2
2
Sepsis
2
3
Unspecified Infection
2
2
Discomfort
1
1
Blood Loss
1
1
Abscess
1
1
Anemia
1
1
Shock
1
2
Hematoma
1
2
Ulcer
1
1
Necrosis
1
1
Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available
1
2
Dysphasia
1
1
Respiratory Insufficiency
1
1
Airway Obstruction
1
1
Low Blood Pressure/ Hypotension
1
2
Aspiration Pneumonitis
1
1
-
-