Class 2 Device Recall Zenostar MT Color Impulse |
|
Date Initiated by Firm |
May 27, 2016 |
Create Date |
October 04, 2016 |
Recall Status1 |
Terminated 3 on June 14, 2018 |
Recall Number |
Z-0017-2017 |
Recall Event ID |
74320 |
510(K)Number |
K152118
|
Product Classification |
Powder, porcelain - Product Code EIH
|
Product |
Zenostar MT Color Impulse blue, Art. no. 681165
Product Usage: For coloring dental porcelain
|
Code Information |
Lot No: U54839, expiration date: Jan 25 2018; Lot No: U51735, expiration date: Nov 11 2017; Lot No: U49940, expiration date: Nov 2 2017; Lot No: U44391, expiration date: Oct 19 2017 and Lot No: U39253, expiration date: Sep 20 2017 |
Recalling Firm/ Manufacturer |
Ivoclar Vivadent, Inc. 175 Pineview Dr Amherst NY 14228-2231
|
For Additional Information Contact |
Donna Marie Hartnett 716-691-0010
|
Manufacturer Reason for Recall |
The primary packaging of these products may show leaks in individual cases. As a consequence, the liquid may escape inadvertently and direct contact with this liquid may lead to skin irritation.
|
FDA Determined Cause 2 |
Process design |
Action |
Wieland sent an Urgent Medical Device Recall Notification letters dated May 27, 2016, and Response Forms to their customers via courier service to customers. The letter identified the affected product, problem and actions to be taken. Customers were instructed to Segregate any affected materials immediately. Customers were asked to complete the attached Acknowledgment form and return it to Ivoclar Vivadent, Inc. by mail, fax or email as indicated on the form. For questions contact Ivoclar Vivadent Technical Customer Service at 800-533-6825. |
Quantity in Commerce |
79 units |
Distribution |
US Nationwide Distribution in the states of: AK, AL, AZ, CA, CO, CT, FL, IA, IL, IN, KS, LA, MA, MD, MI, MN, MO, NC, ND, NE, NJ, NY, OH, OR, PA, TN, TX, UT, VA, WA, and WI. |
Total Product Life Cycle |
TPLC Device Report
|
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls.
2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall.
3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 §7.55.
|
510(K) Database |
510(K)s with Product Code = EIH and Original Applicant = WIELAND DENTAL + TECHNIK GMBH & CO. KG
|
|
|
|