| Date Initiated by Firm | November 21, 2017 |
| Create Date | June 01, 2018 |
| Recall Status1 |
Terminated 3 on October 27, 2020 |
| Recall Number | Z-1884-2018 |
| Recall Event ID |
78975 |
| |
| Product Classification |
Low-power laser light show projector - Product Code RDZ
|
| Product | Santajoy Ornament & Giftware Co., Ltd E-Z Illuminations Northern Lights E-Z Illuminations Galaxy
Laser projectors that emit various colors and light patterns for entertainment and decorative purposes. |
| Code Information |
Model No: EZ-Illuminations Galaxy , EZ-Illuminations Northern Lights |
| FEI Number |
3012680817
|
Recalling Firm/ Manufacturer |
SANTA JOY ORNAMENT & GIFTWARE CO
3rd Block Changtian Ind
Hengli Town
Dongguan City
China
|
| For Additional Information Contact | 410-540-9840 |
Manufacturer Reason for Recall | It was discovered that the product units it imported may, at peak levels, emit radiation that exceeds the federal standard for Class IIIa products. |
FDA Determined Cause 2 | Nonconforming Material/Component |
| Action | The Firm will bring the device into compliance by :
1. Santa Joy Ornament (SJO) will provide a full refund in exchange for the return of the models listed above. Returned products will be destroyed.
2. SJO has purchased optical measurement equipment and intends to measure the output of each laser product and ensure all laser products comply with applicable performance standards before shipment.
CDRH approves the CAP subject to the following conditions:
1. Notification of all dealers and purchasers is to be made within 15 working days of receipt of this letter in the manner specified in 21 CFR 1003.21 and 1003.22. This office and the Food and Drug Administration (FDA) district office coordinator noted below are to be included in the notification. For further questions, please call (410) 540-9840. |
| Quantity in Commerce | 433,128 |
| Distribution | USA (nationwide) distribution |
| Total Product Life Cycle | TPLC Device Report |
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls. 2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall. 3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 �7.55.
|