• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

Class 2 Device Recall EZ Illuminations Northern Lights EZ Illuminations Galaxy

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 


New Search Back to Search Results
 Class 2 Device Recall EZ Illuminations Northern Lights EZ Illuminations Galaxysee related information
Date Initiated by FirmNovember 21, 2017
Create DateJune 01, 2018
Recall Status1 Terminated 3 on October 27, 2020
Recall NumberZ-1884-2018
Recall Event ID 78975
Product Classification Low-power laser light show projector - Product Code RDZ
ProductSantajoy Ornament & Giftware Co., Ltd E-Z Illuminations Northern Lights E-Z Illuminations Galaxy Laser projectors that emit various colors and light patterns for entertainment and decorative purposes.
Code Information Model No: EZ-Illuminations Galaxy , EZ-Illuminations Northern Lights  
FEI Number 3012680817
Recalling Firm/
Manufacturer
SANTA JOY ORNAMENT & GIFTWARE CO
3rd Block Changtian Ind
Hengli Town
Dongguan City China
For Additional Information Contact
410-540-9840
Manufacturer Reason
for Recall
It was discovered that the product units it imported may, at peak levels, emit radiation that exceeds the federal standard for Class IIIa products.
FDA Determined
Cause 2
Nonconforming Material/Component
ActionThe Firm will bring the device into compliance by : 1. Santa Joy Ornament (SJO) will provide a full refund in exchange for the return of the models listed above. Returned products will be destroyed. 2. SJO has purchased optical measurement equipment and intends to measure the output of each laser product and ensure all laser products comply with applicable performance standards before shipment. CDRH approves the CAP subject to the following conditions: 1. Notification of all dealers and purchasers is to be made within 15 working days of receipt of this letter in the manner specified in 21 CFR 1003.21 and 1003.22. This office and the Food and Drug Administration (FDA) district office coordinator noted below are to be included in the notification. For further questions, please call (410) 540-9840.
Quantity in Commerce433,128
DistributionUSA (nationwide) distribution
Total Product Life CycleTPLC Device Report

1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls.
2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall.
3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 �7.55.
-
-