|
Class 2 Device Recall BIOFIRE Respiratory Panel 2.1 (RP2.1),
(Firm Part Number 423742) |
|
Date Initiated by Firm |
November 27, 2023 |
Date Posted |
January 10, 2024 |
Recall Status1 |
Open3, Classified |
Recall Number |
Z-0704-2024 |
Recall Event ID |
93526 |
Product Classification |
Multi-target respiratory specimen nucleic acid test including SARS-CoV-2 and other microbial agents - Product Code QOF
|
Product |
The BIOFIRE Respiratory Panel 2.1 (RP2.1) is a PCR-based multiplexed nucleic acid test intended for use with the BIOFIRE FILMARRAY 2.0 or BIOFIRE FILMARRAY Torch Systems. |
Code Information |
UDI-DI: 00815381020529. Kit Lot/Pouch Lot/Expiration: 1667923/2X2423/June 26, 2024; 1890223/2YHT23/July 26, 2024 |
Recalling Firm/ Manufacturer |
BioFire Diagnostics, LLC 515 S Colorow Dr Salt Lake City UT 84108-1248
|
For Additional Information Contact |
Customer Support Department 800-736-6354 Ext. 5
|
Manufacturer Reason for Recall |
A manufacturing event may contribute to elevated rates of false negative results while using gastrointestinal panel and respiratory panel, which could lead to inappropriate antibiotic treatment, no treatment, delay of treatment, and may provide false assurance to someone with a true infection, delayed identification of an outbreak, and may result in additional transmission.
|
FDA Determined Cause 2 |
Process control |
Action |
On 11/27/23, recall notices were emailed to laboratory directors who were asked to do the following:
Discontinue use and discard any remaining pouches that are subject to this recall.
Distribute this information to all appropriate personnel in your laboratory, retain a copy in your files, and forward this information to all parties that may use this product, including others to whom you may have transferred our product.
Complete and return the acknowledgement form using the following URL: https://www.biofiredx.com/recall5797
Customers with questions can contact Technical Support at biofiresupport@biomerieux.com or via telephone by dialing 1.800.735.6544 and selecting option 5. |
Quantity in Commerce |
57 Kits |
Distribution |
US: NC, MO, NE, CT, IL, TN, NJ, OH, MA, CA, FL, UT, IA, KS, TX, MD
|
Total Product Life Cycle |
TPLC Device Report
|
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls.
2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall.
3 The manufacturer has initiated the recall and not all products have been corrected or removed. This record will be updated as the status changes.
|
|
|
|