| | Class 2 Device Recall VerifyNow P2Y12 Assay Device Kit |  |
| Date Initiated by Firm | September 05, 2006 |
| Date Posted | December 06, 2006 |
| Recall Status1 |
Terminated 3 on March 26, 2012 |
| Recall Number | Z-0228-2007 |
| Recall Event ID |
36707 |
| 510(K)Number | K051231 |
| Product Classification |
Platelet assay, automated - Product Code JOZ
|
| Product | VerifyNow P2Y12 Assay Device Kit, Part Number 85054 |
| Code Information |
Lot Numbers: WK0002A , WK0003A, WK0003B, WK0004A , WK0005A , WK0006A, WK0006AR, WK0006B, WK0006BR, WK0007A, WK0008A, WK0009A, WK0010A ,WK0010B, 10WK000C, WK0011A, WK0012A and WK0013A |
| FEI Number |
3001376288
|
Recalling Firm/ Manufacturer |
Accumetrics Inc
3985 B Sorrento Valley Blvd
San Diego
CA
92121
|
| For Additional Information Contact | Roberta G. Hoffman 888-919-9333 Ext. 218 |
Manufacturer Reason for Recall | The VerifyNow P2Y12 assay can report an erroneous result instead of an error message when a sample with low hematocrit is run. |
FDA Determined Cause 2 | Other |
| Action | The 333 consignees were notified by regular mail or by E-mail on 9/5/2006 -- 9/13/2006. There were four versions of the notification letter tailored to (1) domestic customers; (2) domestic distributors; (3) international customers; and (4) international distributors. Each notification was accompanied by a 'fax back' form which customers were asked to sign and return to Accumetrics as an acknowledgement they received the notification letter.
The notification letter instructs consignees that test results with the VerifyNow P2Y12 Assay and all VerifyNow assays should be interpreted in conjunction with other clinical and laboratory data available to the clinician. Caution is advised when testing patients outside the ranges documented in the package insert.
|
| Quantity in Commerce | 333 |
| Distribution | Worldwide Distribution- USA, and countries of Australia, Canada, France, Germany, Italy, Japan, Korea, Malaysia, Netherlands, New Zealand, Norway, Poland, Singapore, Spain, Sweden, Switzerland, & United Kingdom |
| Total Product Life Cycle | TPLC Device Report |
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls. 2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall. 3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 �7.55.
|
| 510(K) Database | 510(K)s with Product Code = JOZ
|
|
|
|