| Part B: Supplementary Information Sheet (SIS) |
|
FR Recognition List Number
|
064
|
Date of Entry 05/26/2025
|
|
FR Recognition Number
|
13-142
|
| Standard | |
FIRST CVSS v3.1 Common Vulnerability Scoring System version 3.1 |
|
Scope/Abstract| The Common Vulnerability Scoring System (CVSS) is an open framework for communicating the characteristics and severity of software vulnerabilities. CVSS consists of three metric groups: Base, Temporal, and Environmental. The Base group represents the intrinsic qualities of a vulnerability, the Temporal group reflects the characteristics of a vulnerability that change over time, and the Environmental group represents the characteristics of a vulnerability that are unique to a user's environment. The Base metrics produce a score ranging from 0 to 10, which can then be modified by scoring the Temporal and Environmental metrics. A CVSS score is also represented as a vector string, a compressed textual representation of the values used to derive the score. |
|
| Extent of Recognition
|
Rationale for Recognition
This standard is relevant to medical devices and is recognized on its scientific and technical merit and/or because it supports existing regulatory policies.
NOTE: Conformance to this standard may not satisfy all the cybersecurity requirements outlined in Section 524B of FD&C Act or the recommendations in the (1) listed below (Relevant FDA Guidance). Manufacturers should consider the information contained within these resources in their assessment of cybersecurity for their device. |
|
Transition Period
| FDA recognition of FIRST CVSS v3.1 [Rec# 13-142] will be superseded by recognition of FIRST CVSS v4.0 [Rec# 13-140]. FDA will accept declarations of conformity, in support of premarket submissions, to [Rec# 13-142] until July 4, 2027. After this transition period, declarations of conformity to [Rec# 13-142] will not be accepted. |
|
Relevant FDA Guidance and/or Supportive Publications*
1. Cybersecurity in Medical Devices: Quality System Considerations and Content of Premarket Submissions, Guidance for Industry and Food and Drug Administration Staff, issued June 2025.
2. Postmarket Management of Cybersecurity in Medical Devices, Guidance for Industry and Food and Drug Administration Staff, issued December 2016.
Appropriate Use of Voluntary Consensus Standards in Premarket Submissions for Medical Devices - Guidance for Industry and Food and Drug Administration Staff, issued September 2018. |
|