| Part B: Supplementary Information Sheet (SIS) |
|
FR Recognition List Number
|
065
|
Date of Entry 12/22/2025
|
|
FR Recognition Number
|
11-428
|
| Standard | |
ASTM F1541-24 Standard Specification and Test Methods for External Skeletal Fixation Devices |
|
Scope/Abstract1.1 This specification provides a characterization of the design and mechanical function of external skeletal fixation devices (ESFDs), test methods for characterization of ESFD mechanical properties, and identifies needs for further development of test methods and performance criteria. The ultimate goal is to develop a specification which defines performance criteria and methods for measurement of performance-related mechanical characteristics of ESFDs and their fixation to bone. It is not the intention of this specification to define levels of performance or case-specific clinical performance of the devices, as insufficient knowledge is available to predict the consequences of the use of any of these devices in individual patients for specific activities of daily living. Furthermore, it is not the intention of this specification to describe or specify specific designs for ESFDs.
1.2 This specification describes ESFDs for surgical fixation of the skeletal system. It provides basic ESFD geometrical definitions, dimensions, classification, and terminology; material specifications; performance definitions; test methods; and characteristics determined to be important to the in vivo performance of the device. |
|
| Extent of Recognition
|
Rationale for Recognition
| This standard is relevant to medical devices and is recognized on its scientific and technical merit and/or because it supports existing regulatory policies. |
|
Transition Period
| FDA recognition of ASTM F1541-17 [Rec# 11-322] will be superseded by recognition of ASTM F1541-24 [Rec# 11-428]. FDA will accept declarations of conformity, in support of premarket submissions, to [Rec# 11-322] until December 19, 2027. After this transition period, declarations of conformity to [Rec# 11-322] will not be accepted. |
|
Public Law, CFR Citation(s) and Procode(s)*
| Regulation Number |
Device Name |
Device Class |
Product Code |
| §888.3030 |
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component
|
Class 2
|
KTT
|
| §888.3040 |
Pin, Fixation, Smooth
|
Class 2
|
HTY
|
| §888.3040 |
Pin, Fixation, Threaded
|
Class 2
|
JDW
|
|
Relevant FDA Guidance and/or Supportive Publications*
Reviewers Guidance Checklist for Orthopedic External Fixation Devices Version #5, issued February 1997.
Appropriate Use of Voluntary Consensus Standards in Premarket Submissions for Medical Devices - Guidance for Industry and Food and Drug Administration Staff, issued September 2018. |
|
| FDA Technical Contact
|
| Standards Development Organization
|
| FDA Specialty Task Group (STG)
|
|
|
| *These are provided as examples and others may be applicable. |