• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: CAREFUSION 303, INC. BD Pyxis¿ Anesthesia Station ES; Automated Dispensing Cabinet

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CAREFUSION 303, INC. BD Pyxis¿ Anesthesia Station ES; Automated Dispensing Cabinet Back to Search Results
Model Number 500400001500
Medical Device Problem Code Application Program Problem (2880)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/17/2026
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that when using the bd pyxis¿ anesthesia station es, the system had ransomware attack, all the stations were on critical override and resync devices procedure on going.\ however, there were no delays or adverse events or injuries reported based on this event.
 
Additional Manufacturer Narrative
A review of the complaint history for sn (b)(6)was performed in salesforce which did not locate similar complaint(s) with the same failure mode for this serial number.\ \ a review of the device history record for sn (b)(6)was performed from the date of manufacture, 26-mar-2024 and confirmed that this device was not previously returned for servicing and there were no production failures which correlates to the customer reported issue.\ \ upon investigation of the actual device used in this incident, it was determined that the system had ransomware attack, all the stations were on critical override and resync devices procedure on going.A technical support specialist (tss) dialed into the station, logged in as carefusion admin, opened sql server management studio and executed the required station query in accordance with knowledge article \"es 1.7.X + datasync 2.0\", verified all transactions had been queued locally and successfully processed at the server, completed a station database backup following knowledge article \"how to create a station database backup\", opened the medes application and confirmed the upload queue size was 0 within sync status, performed a full station sync in accordance with knowledge article \"proper data sync 2.0 procedure\" without dropping the station database, configured station auto login as carefusion application and rebooted the station, dialed into the med es application server, executed the required structured query language query to review the station synchronization status, confirmed the expired message flag value was 0 in accordance with knowledge article \"expired messages in es 1.7\" indicating the expired message condition had been cleared, sent an email to the customer advising that the requested activities had been completed and verified successfully to resolve the issue.The system functioned as intended after the technical support specialist troubleshot the device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD Pyxis¿ Anesthesia Station ES
Common Device Name
Automated Dispensing Cabinet
Manufacturer (Section D)
CAREFUSION 303, INC.
3750 torrey view ct
san diego CA 92130
Manufacturer (Section G)
CareFusion 303, INC.
10020 pacific mesa blvd
san diego CA 92121 -438
Manufacturer Contact
brett wilko
3750 torrey view ct
san diego, CA 92130
+1(858)617-2000
MDR Report Key51119565
Report Number2016493-2026-72265
Device Sequence Number13524432
Product Code BRY
UDI-Device Identifier10885403533242
UDI-Public(01)10885403533242
Combination Product (Y/N)N
Initial Reporter StateMD
Initial Reporter CountryUS
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 10/05/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Model Number500400001500
Device Catalogue Number327
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/17/2026
Initial Report FDA Received Date10/16/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured03/26/2024
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient SexUnknown
-
-